11.07.2015 Views

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fur<strong>the</strong>r examinations should be done concerning <strong>the</strong> influence <strong>of</strong> weakness, betterreproducibility and especially fatigue loading.REFERENCES:[1] Beaver RJ et al., Proc. 7 th BIOLOX ® Symposium, 65-71, 2002FiguresPoster: 77Influence <strong>of</strong> Impacting Ceramic Inserts on Proper Seating in AcetabularCups for Hip ImplantsINTRODUCTION:*Thomas Pandorf - CeramTec AG - Plochingen, GermanyRoman Preuss - CeramTec AG - Plochingen, GermanyHendrik Bertmaring - CeramTec AG - Plochingen, Germany*Email: t.pandorf@ceramtec.decThe advantage <strong>of</strong> a modular system is that <strong>the</strong> surgeon is able to choose <strong>the</strong> metal cup andinsert to adapt <strong>the</strong> implant system to <strong>the</strong> individual needs <strong>of</strong> a patient. During preoperativeplanning an appropriate combination is chosen. During surgery facing deviant conditions it ispossible to change decision choosing ano<strong>the</strong>r insert size or material. Beside <strong>the</strong> benefitdisadvantages exist caused by a modular connection technique. The ceramic insert isrecommended as being manually assembled during surgery into a dry and clean metal cup bypushing it in along <strong>the</strong> metal taper. Fur<strong>the</strong>rmore, a slight axial tap using a plastic impactorshould be applied onto <strong>the</strong> insert to assure a secure connection. According to investigationsrelated to current surgical practice, it has been found that during <strong>the</strong> intraoperative assembly <strong>of</strong>insert and metal cup, <strong>the</strong> forces applied by <strong>the</strong> surgeon show a large deviation. In some cases,<strong>the</strong> surgeons even avoided <strong>the</strong> impaction 1 . In some cases surgeons even avoided <strong>the</strong> impaction.Under in-vivo conditions adhesion forces generated between ball head and insert due to <strong>the</strong>synovia fluid might transfer tension forces between ball head and inserts. Occurring microseparation <strong>of</strong> <strong>the</strong> head consequently leads to pull-out loading <strong>of</strong> <strong>the</strong> insert.This study shows <strong>the</strong> importance <strong>of</strong> a slight axial tap for a secure connection by examining <strong>the</strong>effects <strong>of</strong> occurring adhesion between ball head and insert.METHODS:file:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!