11.07.2015 Views

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Conclusions.Fixed valgus angle resection is not reliable in restoring mechanical axis in total kneearthroplasty. In <strong>the</strong> absence <strong>of</strong> facilities for surgical navigation, a pre operative planning withlong leg films is extremely important to achieve long-term success.Friday, October 8, 2010, 15:20-16:00Session B14: Hip ResurfacingHip Implants - Tribological Testing Influenced by Physiological Conditions*Joseph Pamu - Smith & Nephew - Leamington Spa, EnglandAmir Kamali - Smith & Nephew - Leamington Spa, EnglandJasper Daniel - - , United KingdomAzad Hussain - Smith & Nephew Orthopaedics Ltd - Leamington Spa, UKChenxi Li - Smith & Nephew Orthopaedics Ltd - Leamington Spa, England*Email: joseph.pamu@smith-nephew.comIntroduction: Hip implant research has been carried out for decades using hip simulators toreflect situations in vivo. With regards to metal on metal (MoM) implant testing, it has beenreported that <strong>the</strong>re is no significant difference between <strong>the</strong> wear generated by various cobaltchromium (CoCr) microstructures. On <strong>the</strong> contrary, higher wear, metal ion levels andsubsequent failures have been reported in heat treated (high carbon, low carbide) devicescompared to as cast (high carbon, high carbide) devices in vivo. During testing, <strong>the</strong> bearingsurfaces may be masked from <strong>the</strong> effect <strong>of</strong> microstructure on wear <strong>under</strong> fast and continuouscycles, while in vivo, <strong>the</strong> extensive range <strong>of</strong> kinetics and kinematics, stop/start motion, varyingwalking frequencies could break down <strong>the</strong> fluid film, resulting in a less favourable lubricationregime. The aims <strong>of</strong> this study were to develop a more physiologically relevant hip simulatortest protocol, and investigate <strong>the</strong> effect <strong>of</strong> microstructure on wear.Materials & Methods: Three pairs <strong>of</strong> 50mm as cast (AC) and four pairs <strong>of</strong> 50mm double heattreated (DHT) CoCr MoM devices were tested in a ProSim hip simulator. In order to determine<strong>the</strong> frequency for testing, Patients’ activities have been monitored using a Step Activity Monitor(SAM) device. The data showed a relatively slower walking pace (frequency) than that used in<strong>the</strong> hip simulator studies. The new frequency, along with stop/start motion and various kineticsand kinematics pr<strong>of</strong>iles have been used in putting toge<strong>the</strong>r a more physiologically relevant hipsimulator test protocol. The lubricant used in this study was new born calf serum with 0.2 %(w/v) sodium azide concentration diluted with de-ionised water to achieve an average proteinconcentration <strong>of</strong> 20 g/l. Gravimetric measurements have been taken at 0.5, 1, 1.5 & 2 millioncycle (Mc) stages and ion analysis has been carried out on <strong>the</strong> serum samples.Results & Discussions: A biphasic wear pattern similar to <strong>the</strong> parts in vivo was observed.Under <strong>the</strong> newly developed physiologically relevant test conditions, <strong>the</strong> DHT CoCr devicesgenerated 40% higher wear than <strong>the</strong> AC CoCr devices (Figure 1).The metal ion analysis results also showed a similar biphasic wear trend, however, <strong>the</strong>difference between <strong>the</strong> AC and DHT devices was fur<strong>the</strong>r increased by approximately 30 % at 2file:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!