11.07.2015 Views

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

age limit for THA can be lowered.Friday, October 8, 2010, 11:10-11:50Session A13: Alternate Bearing Materials in ArthroplastyModified Minimally Invasive Two-Incision THA Using Large-DiameterCeramic-on-Ceramic Articulation*Yoon Taek Rim - Chonnam National University - Hwasun-Gun, KoreaPark Young Hoon - Chonnam National University - Hwasun-Gun, KoreaCho Nam Young - Chonnam National University - Hwasun-Gun, Korea*Email: tryoon@chonnam.ac.krThe authors modified <strong>the</strong> original minimally invasive (MI) two-incision total hip arthroplasty(THA) technique and used large-diameter (32mm, 36mm) ceramic-on-ceramic articulation. Onehundred and seventy patients that <strong>under</strong>went unilateral MI two-incision THA retrospectivelyreviewed, and surgical morbidities, functional recoveries, radiological implantation properties,and complications were assessed. The mean follow-up was 30.2 months (range, 24-42 months)and mean patient age was 50.4 years (range, 22-83 years). In <strong>the</strong> lateral position, ananterolateral approach between <strong>the</strong> gluteus medius and tensor fascia lata and a posteriorapproach between <strong>the</strong> piriformis and gluteus medius was used. Mean operation time was 71.2minutes (range, 48-91 minutes). Mean Harris hip score improved from 41.8 (range, 10-59) to96.1 (range, 73-100) at last follow-up, and mean WOMAC score from 66.2 (range, 49-96) to26.9 (range, 24-39). The mean lateral opening angle <strong>of</strong> <strong>the</strong> acetabular component was 38.2°(range, 32.1°-47.7°) and <strong>the</strong> mean stem position was valgus 1.9° (range, varus 2.3° to valgus4.8°). One patient suffered an intraoperative femur fracture and ano<strong>the</strong>r <strong>under</strong>went revisionsurgery due to stem subsidence. No patient experienced dislocation. Our data suggest <strong>the</strong> thismodified technique is safe and reproducible in terms <strong>of</strong> achieving proper implant positioningand early functional recovery. In particular, <strong>the</strong> complication rates encountered, especially <strong>the</strong>dislocation rate, were low.Thursday, October 7, 2010, 8:00-8:50Session A1: Alternate Bearings in THA 1file:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!