11.07.2015 Views

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FiguresPoster: 14Exchanging Polyethylene Liner With Cement Fixation in Well-FixedCementless Acetabular Cup*Yoon Je Cho - Kyung Hee University - Seoul, KoreaSang Joon Kwak - Kyung Hee University - Seoul, Republic <strong>of</strong> KoreaYoung Soo Chun - - ,Kee Hyung Rhyu - Center for Joint Disease, Kyung Hee University East-West Neo MedicalCenter - Seoul, KoreaChul Hee Park - Kyung Hee University - Seoul, KoreaMyung Chul Yoo - Kyung Hee University - Seoul, Korea*Email: yjcho@khmc.or.krPurpose: To analyze <strong>the</strong> short-term results <strong>of</strong> exchanging polyethylene(PE) liner with cementfixation in retained stable cementless acetabular cup.Materials and Methods: A consecutive series <strong>of</strong> 19 hips <strong>of</strong> 19 patients who <strong>under</strong>went revisiontotal hip arthroplasty(THA) exchanging <strong>the</strong> liner with cement fixation in <strong>the</strong> retained stableacetabular cup were evaluated at an average follow-up <strong>of</strong> 38.9 months (24~75 months). Thecauses <strong>of</strong> revision surgery were liner wear and liner dislodging in all cases. There were 3 kinds<strong>of</strong> retained cementless cups, Harris-Galante(HG) II in 16hips, HG I in 2 hips and AML in 1 hip.There was a breakage <strong>of</strong> locking mechanism in 16 hips. There were 3 hips without breakage <strong>of</strong>locking mechanism, and it was a case <strong>of</strong> metal cup malposition, metal shell damage, and cupdislodging without tyne damage. All <strong>of</strong> <strong>the</strong> PE liner was exchanged into <strong>the</strong> cross-linked PEliner except with a case with low pr<strong>of</strong>ile cup. In all cases, bone graft as an additional procedurewas performed for <strong>the</strong> osteolysis around <strong>the</strong> acetabular components. Clinically, Harris hipscores, hip pain, limping and ROM were evaluated. Radiological changes, such as osteolysis,liner dissociation and wear, and bone graft incorporation were analyzed in consecutive series <strong>of</strong>radiographs.Results: There was no case <strong>of</strong> re-revision surgery. There was a satisfactory improvement inHarris hip score from an average <strong>of</strong> 74.5 to 91.5. We could not find any cases with liner wearand liner dissociation from <strong>the</strong> cement fixation. There was no sign <strong>of</strong> alteration in <strong>the</strong> stability<strong>of</strong> polyethylene liner. The size <strong>of</strong> <strong>the</strong> osteolytic lesions significantly reduced postoperatively.Nei<strong>the</strong>r new osteolytic lesions nor a progression <strong>of</strong> Osteolysis were seen at <strong>the</strong> latest follow-upin bone graft area except a case with partial bone resorption. As a complications, <strong>the</strong>re havebeen 4 cases <strong>of</strong> hip dislocation. None <strong>of</strong> <strong>the</strong>se patients experienced recurrent dislocation afterprimary closed reduction.Conclusion: Exchanging a PE liner with cement fixation revealed satisfactory short-termresults. The result <strong>of</strong> <strong>the</strong> study demonstrates that <strong>the</strong> indication <strong>of</strong> this operation technique canfile:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!