11.07.2015 Views

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

Convened under the auspicious of esteemed endorsers - ISTA

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Mortality was 10% at 3 months, 22% at 1 year and 47% at 3 years.We have identified that union can be achieved in <strong>the</strong> majority <strong>of</strong> cases after peripros<strong>the</strong>ticfracture fixation. Cable fixation was associated with a high complication rate (7 cases: tworequiring revision surgery: one nonunion, one malunion).We recommend that Vancouver B1 peripros<strong>the</strong>tic fractures are treated with meticuloustechnique to achieve anatomical reduction and fracture compression using lag screw techniqueand plating. Fur<strong>the</strong>r mechanical support can be provided through <strong>the</strong> use <strong>of</strong> a second plate,cables and/or strut grafts.FiguresSaturday, October 9, 2010, 9:00-9:30Session B17: Novel techniques in ArthroplastyAcetabular Reconstruction in Severe Bone Defects Using a New Cup WithIliac Screw: Presentation and Preliminary ResultsGiovanni Pignatti - Rizzoli Orthopedic Institute - Bologna, ItalyDante Dallari - - Medicina,*Nicola Rani - Istituti Rizzoli Bologna - Bologna, ItalyCesare Stagni - Rizzoli Orthopedic Institute - Bologna, ItalyNicolandrea Del Piccolo - Istituti Rizzoli Bologna - Bologna, ItalyArmando Giunti - - Bologna,*Email: nicola.rani@tiscali.itINTRODUCTION: Since July 2008 we are experimenting a new cup with iliac screw fixation,developed on <strong>the</strong> idea <strong>of</strong> Ring and Mc Minn. Iliac fixation is permitted by a polar screw <strong>of</strong>large diameter, coated by HA, which allows a compression to bone and a firm primary stability.Moreover it's possible to increase primary stability with fur<strong>the</strong>r smaller peripherals screws. Wepresent this new cup and report <strong>the</strong> preliminary results.MATERIALS AND METHOD: Since July 2008 to April 2010, 51 cups were implanted. Thediagnosis was aseptic loosening in 36 cases, septic loosening treated by two-stage revision in 7,hip congenital dislocation in 5, one case <strong>of</strong> post-traumatic osteoarthritis, one case <strong>of</strong> instabilitydue to cup malposition and a case was an outcome <strong>of</strong> Girdlestone resection arthroplasty. Meanage was <strong>of</strong> 66 years (31-90).RESULTS: We report <strong>the</strong> results <strong>of</strong> our first 23 cases, with a minimal follow-up <strong>of</strong> 12 months.Patients were preoperatively evaluated from both clinical and radiological point <strong>of</strong> view. Bonedefect was analyzed according to <strong>the</strong> system <strong>of</strong> Paprosky. In 7 cases bone defect belonged totype 2C, in 8 cases to type 3A and in 8 cases to type 3B. We didn't observe any case <strong>of</strong> earlyloosening nor mechanical failure <strong>of</strong> <strong>the</strong> implant. The functional outcome, evaluated by HarrisHip Score, was good with a mean score <strong>of</strong> 82 (72-91).file:///E|/<strong>ISTA</strong>2010-Abstracts.htm[12/7/2011 3:15:47 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!