TABLE 6.15 Typical Pile Characteristics <strong>and</strong> Uses (Continued)<br />

6.94<br />

Pile type<br />

Concrete filled<br />

steel pipe piles Composite piles<br />

Precast concrete<br />

(including prestressed)<br />

Maximum length Practically unlimited 55 m (180 ft) 30 m (100 ft) for precast<br />

60 m (200 ft) for<br />

prestressed<br />

Optimum length 12–36 m (40–120 ft) 18–36 m (60–120 ft) 12–15 m (40–50 ft) for<br />

precast<br />

18–30 m (60–100 ft) for<br />

prestressed<br />

Applicable<br />

material<br />

specifications<br />

Recommended<br />

maximum<br />

stresses<br />

Maximum load<br />

for usual<br />

conditions<br />

Optimum-load<br />

range<br />

ASTM A36 for core<br />

ASTM A252 for pipe<br />

ACI Code 318 for<br />

concrete<br />

0.40 ƒ y reinforcement �<br />

205 MPa (30 ksi)<br />

0.50 ƒ y for core � 175<br />

MPa (25 ksi)<br />

0.33 for concrete<br />

ƒ� c<br />

1800 kN (400 kips)<br />

without cores<br />

18,000 kN (4000 kips)<br />

for large sections with<br />

steel cores<br />

700–1100 kN (160–250<br />

kips) without cores<br />

4500–14,000 kN (1000–<br />

3100 kips) with cores<br />

ACI Code 318 for<br />

concrete<br />

ASTM A36 for<br />

structural section<br />

ASTM A252 for steel<br />

pipe<br />

ASTM D25 for timber<br />

Same as concrete in<br />

other piles<br />

Same as steel in other<br />

piles<br />

Same as timber piles for<br />

wood composite<br />

ASTM A15 reinforcing<br />

steel<br />

ASTM A82 cold-drawn<br />

wire<br />

ACI Code 318 for<br />

concrete<br />

0.33 unless local<br />

ƒ� c<br />

building code is less;<br />

0.4 ƒ y for reinforced<br />

unless prestressed<br />

1800 kN (400 kips) 8500 kN (2000 kips) for<br />

prestressed<br />

900 kN (200 kips) for<br />

precast<br />

250–725 kN (60–160<br />

kips)<br />

350–3500 kN (80–800<br />

kips)<br />

Cast in place<br />

(thin shell driven<br />

with m<strong>and</strong>rels)<br />

30 m (100 ft) for<br />

straight sections<br />

12 m (40 ft) for tapered<br />

sections<br />

Auger placed<br />

pressure-injected<br />

concrete (grout) piles<br />

9–25 m (30–80 ft)<br />

12–18 m (40–60 ft) for 12–18 m (40–60 ft)<br />

straight<br />

5–12 m (16–40 ft) for<br />

tapered<br />

ACI See ACIa 0.33 ; ƒ s � 0.4 ƒ y if<br />

ƒ� c<br />

shell gauge is � 14;<br />

use ƒ s � 0.35 ƒ y if<br />

shell thickness � 3<br />

mm<br />

0.225–0.4ƒ� c<br />

675 kN (150 kips) 700 kN (160 kips)<br />

250–550 kN (60–120<br />

kips)<br />

350–550 kN (80–120<br />

kips)