10.36 SECTION TEN<br />

panels, primarily s<strong>and</strong>ed grades, is based on the species used for face <strong>and</strong> back<br />

veneers. Where face <strong>and</strong> back veneers are not from the same species group, the<br />

higher group number is used, except for s<strong>and</strong>ed panels 3 ⁄8 in thick or less <strong>and</strong><br />

decorative panels of any thickness. These are identified by face species if C or D<br />

grade backs are at least 1 ⁄8 in thick <strong>and</strong> are not more than one species group number<br />

larger. Some species are used widely in plywood manufacture, others rarely.<br />

OSB panels, being composed of flakes or str<strong>and</strong>s instead of veneers, are graded<br />

without reference to veneers or species, <strong>and</strong> composite panels are graded on an<br />

OSB performance basis by end use <strong>and</strong> exposure durability. Typical panel trademarks<br />

for all three panel types <strong>and</strong> an explanation of how to read them are shown<br />

in Fig. 10.5.<br />

The ‘‘<strong>Design</strong>/<strong>Construction</strong> Guide—Residential & Commercial,’’ APA—The Engineered<br />

Wood Association, Tacoma, Wash., contains a comprehensive summary<br />

of plywood grades <strong>and</strong> trademarks <strong>and</strong> their applications.<br />

10.12.4 Span Ratings for Panels<br />

APA Rated Sheathing, APA Rated Sturd-I-Floor, <strong>and</strong> APA Rated Siding carry numbers<br />

in their trademarks called span ratings. These denote the maximum spacing,<br />

in, c to c of supports for panels in construction applications. Except for Rated Siding<br />

panels, the span rating in the trademark applies when the long panel dimension is<br />

across supports, unless the strength axis is otherwise identified. The span rating in<br />

the trademark of Rated Siding panels applies when they are installed vertically.<br />

The span rating in Rated Sheathing trademarks appears as two numbers separated<br />

by a slash (Fig. 10.5a), such as 32/16 <strong>and</strong> 48/24. The left-h<strong>and</strong> number<br />

denotes the maximum recommended spacing of supports when the panel is used<br />

for roof sheathing with the long dimension or strength axis of the panel across three<br />

or more supports. The right-h<strong>and</strong> number indicates the maximum recommended<br />

spacing of supports when the panel is used for subflooring with the long dimension<br />

or strength axis of the panel across three or more supports. A panel marked 32/<br />

16, for example, may be used for roof decking over supports 32 in c to c or for<br />

subflooring over supports 16 in c to c. An exception is Rated Sheathing intended<br />

for use as wall sheathing only. The trademarks for such panels contain only a single<br />

number similar to the span rating for APA Rating Siding <strong>and</strong> Sturd-I-Floor.<br />

The Span Ratings in the trademarks on APA Rated Sturd-I-Floor <strong>and</strong> APA Rating<br />

Siding panels appear as a single number. Rated Sturd-I-Floor panels are designed<br />

specifically for single-floor (combined subfloor-underlayment) applications<br />

under carpet <strong>and</strong> pad. They are manufactured with span ratings of 16, 20, 24, 32,<br />

<strong>and</strong> 48 in.<br />

APA Rated Siding is available with span ratings of 16 <strong>and</strong> 24 in. Span-rated<br />

panels <strong>and</strong> lap siding may be connected directly to studs, or over nonstructural wall<br />

sheathing, or over nailable panel or lumber sheathing (double-wall construction).<br />

Panels <strong>and</strong> lap siding with a span rating of 16 in may be applied directly to studs<br />

spaced 16 in c to c. Those bearing a span rating of 24 in may be connected directly<br />

to studs 24 in c to c. All APA Rated Siding panels may be applied horizontally<br />

directly to studs 16 or 24 in c to c, if horizontal joints are blocked. The span rating<br />

of APA Rated Siding panels refers to the maximum recommended spacing of vertical<br />

rows of nails rather than to stud spacing when the panels are applied to nailable<br />

structural sheathing.