9.50 SECTION NINE<br />

9.46.1 Singly-Reinforced Rectangular Beams<br />

For a rectangular beam, reinforced with only tension steel (Fig. 9.12), the total<br />

tension force in the steel at nominal (ultimate) strength is<br />

It is opposed by an equal compressive force<br />

T � A ƒ � �ƒ bd (9.23)<br />

s y y<br />

C � 0.85ƒ�b� c (9.24)<br />

c 1<br />

where ƒ�c � specified compressive strength of the concrete, psi<br />

c � distance from extreme compression surface to neutral axis<br />

�1 � a constant (given in Art. 9.44)<br />

Equating the compression <strong>and</strong> tension forces at the critical section gives:<br />

�ƒ y<br />

c � d (9.25)<br />

0.85� ƒ�<br />

1 c<br />

The criterion for compression failure is that the maximum strain in the concrete<br />

equals 0.003 in/in. In that case:<br />

0.003<br />

c � d (9.26)<br />

ƒ/E � 0.003<br />

s s<br />

where ƒ s is the steel stress, ksi, <strong>and</strong> E s � 29,000,000 psi is the steel modulus of<br />

elasticity.<br />

Tension-Steel Limitations. Under balanced conditions, the concrete will reach its<br />

maximum strain of 0.003 in/in when the tension steel reaches its yield strength ƒ y.<br />

Then, c as given by Eq. (9.26) will equal c as given by Eq. (9.25). Also, the<br />

reinforcement ratio for balanced conditions in a rectangular beam with tension steel<br />

only becomes:<br />

0.85� ƒ� 87,000<br />

1 c<br />

�b � (9.27)<br />

ƒ 87,000 � ƒ<br />

y y<br />

All structures should be designed to avoid sudden collapse. Therefore, reinforcement<br />

should yield before the concrete crushes. Gradual yielding will occur if the<br />

quantity of tensile reinforcement is less than the balanced percentage determined<br />

by strength design theory. To avoid compression failures, the ACI 318 <strong>Building</strong><br />

Code, therefore limits the reinforcement ratio � to a maximum of 0.75�b. The Code also requires that � for positive-moment <strong>and</strong> negative-moment rein-<br />

forcement be at least 3�ƒ�/ƒ <strong>and</strong> not less than 200/ƒ y to prevent sudden collapse<br />

c y<br />

when the design moment strength is equal to or less than the cracking moment.<br />

This requirement does not apply, however, if the reinforcement area at every section<br />

of the member is at least one-third greater than that required by the factored moment.<br />

The ratio, 200/ƒ y, will govern, except when � 4400 psi. For a statically<br />

determinate T-section with the flange in tension, � should be at least 6�ƒ�/ƒ with<br />

the flange width used for determining �.<br />

For flexural members of any cross-sectional shape, without compression reinforcement,<br />

the tension reinforcement is limited by the ACI 318 <strong>Building</strong> Code so<br />

ƒ� c<br />

c y