WOOD CONSTRUCTION 10.19<br />

creased if the chord is 2 � 4 in or smaller <strong>and</strong> has the narrow face braced by<br />

nailing to wood structural panel sheathing at least 3 ⁄8 in thick in accordance with<br />

good nailing practice. The increased stiffness may be accounted for by multiplying<br />

the design value of the modulus of elasticity E by the buckling stiffness factor C T<br />

in column stability calculations. When the effective column length L e, in, is 96 in<br />

or less, C T may be computed from<br />

KMLe CT � 1 � (10.13)<br />

KE<br />

where K M � 2300 for wood seasoned to a moisture content of 19% or less at time<br />

of sheathing attachment<br />

� 1200 for unseasoned or partly seasoned wood at time of sheathing<br />

attachment<br />

K T � 0.59 for visually graded lumber<br />

� 0.75 for machine evaluated lumber (MEL)<br />

� 0.82 for products with a coefficient of variation of 0.11 or less<br />

When L e is more than 96 in, C T should be calculated from Eq. (10.13) with L e �<br />

96 in. For additional information on wood trusses with metal-plate connections, see<br />

design st<strong>and</strong>ards of the Truss Plate Institute, Madison, Wis.<br />

10.5.13 Shear Stress Factor<br />

For dimension-lumber grades of most species or combinations of species, the design<br />

value for shear parallel to the grain F V is based on the assumption that a split,<br />

check, or shake that will reduce shear strength 50% is present (Art. 4.34). Reductions<br />

exceeding 50% are not required inasmuch as a beam split lengthwise at the<br />

neutral axis will still resist half the bending moment of a comparable unsplit beam.<br />

Furthermore, each half of such a fully split beam will sustain half the shear load<br />

of the unsplit member. The design value F V may be increased, however, when the<br />

length of split or size of check or shake is known <strong>and</strong> is less than the maximum<br />

length assumed in determination of F V, if no increase in these dimensions is anticipated.<br />

In such cases, F V may be multiplied by a shear stress factor C H greater than<br />

unity.<br />

In most design situations, C H cannot be applied because information on length<br />

of split or size of check or shake is not available. The exceptions, when C H can be<br />

used, include structural components <strong>and</strong> assemblies manufactured fully seasoned<br />

with control of splits, checks, <strong>and</strong> shakes when the products, in service, will not<br />

be exposed to the weather. C H also may be used in evaluation of the strength of<br />

members in service. The ‘‘National <strong>Design</strong> Specifications for Wood <strong>Construction</strong>,’’<br />

American Forest & Paper Association, lists values of C H for lumber <strong>and</strong> timber of<br />

various species.<br />

10.6 PRESSURE-PRESERVATIVE TREATMENTS<br />

FOR WOOD<br />

Wood members are considered to be permanent without pressure treatment if located<br />

in enclosed buildings where good roof coverage, proper roof maintenance,<br />

T