9.88 SECTION NINE<br />

column of a flat plate system where the unbalanced moment, M u, resulting from<br />

gravity loads on the slab, must be transferred to the column. The unbalanced moment<br />

is transferred by flexure <strong>and</strong> by eccentricity of shear.<br />

Part of the unbalanced moment, � ƒM u, must be transferred by flexure within an<br />

effective slab width equal to the column width plus 1.5h on side of the column,<br />

i.e., a width of (c 2 � 1.5h) where c 2 is the edge-column width transverse to the<br />

direction in which moments are being determined <strong>and</strong> h is the overall thickness of<br />

the slab. The remaining part of the unbalanced moment, � ƒM u, must be transferred<br />

by eccentricity of shear about the centroid of the critical section which is located<br />

at distance of d/2 from the column where d is the effective depth of the slab. (As<br />

noted in the following discussion, the code supersedes the requirement of designing<br />

for � vM u by prescribing the magnitude of the gravity load moment to be transferred<br />

by eccentricity of shear.) The fractions � ƒ <strong>and</strong> � v are calculated<br />

1<br />

� � (9.78)<br />

ƒ<br />

1 � (2/3) �b /b<br />

1 2<br />

� � (1 � � ) (9.79)<br />

v ƒ<br />

where b 1 � width of critical section measured in the direction in which moments<br />

are being determined<br />

b 2 � width of critical section measured in the direction perpendicular to b 1<br />

For a square edge column <strong>and</strong> square panels, approximately 60% of the unbalanced<br />

moment will be transferred by flexure within the slab width (c 2 � 3h) centered<br />

on the column centerline. The result is that about 60% of the total top reinforcement<br />

required in the column strip must be concentrated within the slab width<br />

(c 2 � 3h) at the edge column. The designer must ensure that the top reinforcing<br />

bars selected can be physically fitted into the width (c 2 � 3h) within allowable bar<br />

spacings, <strong>and</strong> clearly show the bar spacings <strong>and</strong> details on the design drawings.<br />

For transfer of gravity load moment from the slab to the edge column by eccentricity<br />

of shear, the Code prescribes � v(0.3 M o) as the magnitude of the moment<br />

to be transferred, rather than � vM u, where M o is calculated by Eq. (9.72).<br />

For preliminary design, with square columns flush at edges of the flat plate, a<br />

rapid estimate of the shear capacity to allow for effects of combined shear due to<br />

gravity loads <strong>and</strong> to moment transfer can be made by using uniform vertical load<br />

w u only, with nominal strength for factored load as follows:<br />

For edge column, total shear V u � 0.5w uL 2L 1 <strong>and</strong> shear strength V c � 2 b od<br />

�ƒ� c<br />

For first interior column, V u � 1.15w uL 2L 1 <strong>and</strong> shear strength V c � b od<br />

4�ƒ� c<br />

where � specified concrete compressive strength, psi.<br />

ƒ� c<br />

Use of this calculation in establishing a preliminary design is a short cut, which<br />

will often avoid the need for repeating steps 1 through 5 in Art. 9.59.1, because it<br />

gives a close approximation for final design.<br />

The minimum cantilever edge span of a flat plate so that all columns can be<br />

considered interior columns <strong>and</strong> the direct-design method can be used without tedious<br />

stiffness calculations is 4 ⁄15 of the length of the interior span (Fig. 9.29). This<br />

result is obtained by equating the minimum cantilever moment at the exterior column<br />

to the minimum negative-factored moment at the interior column.