Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
12.01<br />
E Siemens AG, 2001. All rights reserved<br />
<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />
10 Measuring Cycles<br />
10.5 Machine data for the measuring cycles sequence<br />
10.5 Machine data for the measuring cycles sequence<br />
10.5.1 Machine data for adapting the probe<br />
Machine data for<br />
adapting the probe<br />
13200 MEAS_PROBE_LOW_ACTIVE [0]<br />
MD number Switching performance of the probe at measuring input 1<br />
Default setting: 0 Min. input limit: 0 Max. input limit: 1<br />
Change valid after POWER ON Protection level: 2/7 Unit: -<br />
Data type: BOOLEAN Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: Value 0: (default setting)<br />
non-deflected state 0 V<br />
deflected state 24 V<br />
Value 1: non-deflected state 24 V<br />
deflected state 0 V<br />
13200 MEAS_PROBE_LOW_ACTIVE [1]<br />
MD number Switching performance of the probe at measuring input 2<br />
Default setting: 0 Min. input limit: 0 Max. input limit: 1<br />
Change valid after POWER ON Protection level: 2/7 Unit: -<br />
Data type: BOOLEAN Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: Value 0: (default setting)<br />
non-deflected state 0 V<br />
deflected state 24 V<br />
Value 1: non-deflected state 24 V<br />
deflected state 0 V<br />
10-151