5.2.3 Description of diagnostics buffer signals<br />
E Siemens AG, 2001. All rights reserved<br />
<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />
5SignalDescription 5.2 Description of <strong>ShopMill</strong> interface DB82<br />
DB82 nck_signal_monitor.monitor_on<br />
DBX60.0 Activate diagnostics function (input signal)<br />
Data block Signal(s) to <strong>ShopMill</strong><br />
Edge evaluation: no Signal(s) updated: cyclically Signal(s) valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Signal meaning The diagnostics function is updated<br />
DB82 nck_signal_monitor.monitor_initialize<br />
DBX60.1 Initialize diagnostics function (input signal)<br />
Data block Signal(s) to <strong>ShopMill</strong><br />
Edge evaluation: no Signal(s) updated: cyclically Signal(s) valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Signal meaning The ring buffer for the diagnostics function is cleared.<br />
DB82 nck_signal_monitor.access_error[m].current_number<br />
DBW n+0 Consecutive No. of error message m (output signal)<br />
Data block Signal(s) from <strong>ShopMill</strong><br />
Edge evaluation: no Signal(s) updated: cyclically Signal(s) valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Signal meaning Consecutive No. of error message m<br />
DB82 nck_signal_monitor.access_error[m].db_number<br />
DBB n+2 DB number of error message m (output signal)<br />
Data block Signal(s) from <strong>ShopMill</strong><br />
Edge evaluation: no Signal(s) updated: cyclically Signal(s) valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Signal meaning DB number of error message m<br />
DB82 nck_signal_monitor.access_error[m].byte_number<br />
DBB n+3 Byte number of error message m (output signal)<br />
Data block Signal(s) from <strong>ShopMill</strong><br />
Edge evaluation: no Signal(s) updated: cyclically Signal(s) valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Signal meaning Byte number of error message m<br />
DB82 nck_signal_monitor.access_error[m].bit_number<br />
DBB n+4 Bit number of error message m (output signal)<br />
Data block Signal(s) from <strong>ShopMill</strong><br />
Edge evaluation: no Signal(s) updated: cyclically Signal(s) valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Signal meaning Bit number of error message m<br />
5-67