02.06.2013 Views

SINUMERIK 840D/810D ShopMill

SINUMERIK 840D/810D ShopMill

SINUMERIK 840D/810D ShopMill

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

12.01<br />

E Siemens AG, 2001. All rights reserved<br />

<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />

10 Measuring Cycles<br />

10.5 Machine data for the measuring cycles sequence<br />

9764 CMM_TOOL_PROBE_ALLOW_AXIS<br />

MD number Permissible axis directions for tool probe (ZYX)<br />

Default setting: 133 Min. input limit: 0 Max. input limit: 333<br />

Change applies from: IMMEDIATE Protection level: 3/4 Unit: -<br />

Data type: WORD Valid as of SW:<br />

<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />

Meaning: This MD defines the permissible axes and the axis directions in which measurements can<br />

be taken at the tool probe.<br />

The number to be specified is made up of ZYX. The following attributes can be specified<br />

for each axis:<br />

0 not possible<br />

1 only in minus direction<br />

2 only in plus direction<br />

3 in both directions<br />

Sample application: Default setting 133 means<br />

1st number: 1 Measuring in Z possible in both directions<br />

2nd number: 3 Measuring in Y possible in both directions<br />

3rd number: 3 Measuring in X possible in both directions<br />

9765 CMM_T_PROBE_DIAM_LENGTH_MEA<br />

MD number Diameter of tool probe for length measurement<br />

Default setting: 0 Min. input limit: 0 Max. input limit: 100000<br />

Change applies from: IMMEDIATE Protection level: 3/4 Unit: mm<br />

Data type: DOUBLE Valid as of SW:<br />

<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />

Meaning: This MD defines the active diameter or the active edge of the tool probe for measurement<br />

of the tool length.<br />

9766 CMM_T_PROBE_DIAM_RAD_MEAS<br />

MD number Diameter of tool probe for radius measurement<br />

Default setting: 0 Min. input limit: 0 Max. input limit: 100000<br />

Change applies from: IMMEDIATE Protection level: 3/4 Unit: mm<br />

Data type: DOUBLE Valid as of SW:<br />

<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />

Meaning: This MD defines the effective diameter or the effective edge of the tool probe for the radius<br />

measurement.<br />

9767 CMM_T_PROBE_DIST_RAD_MEAS<br />

MD number Infeed from top edge of tool probe for radius measurement<br />

Default setting: 0 Min. input limit: 0 Max. input limit: 100000<br />

Change applies from: IMMEDIATE Protection level: 3/4 Unit: mm<br />

Data type: DOUBLE Valid as of SW:<br />

<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />

Meaning: This MD defines the distance between the top edge of the tool probe and the bottom edge<br />

of the tool for the radius measurement.<br />

10-155