10 Measuring Cycles<br />
10.5 Machine data for the measuring cycles sequence<br />
10.5.2 Display machine data for measuring cycles<br />
9750 CMM_MEAS_PROBE_INPUT<br />
MD number Measuring input for a workpiece probe<br />
Default setting: 0 Min. input limit: 0 Max. input limit: 1<br />
Change applies from: IMMEDIATE Protection level: 3/4 Unit: -<br />
Data type: BOOL Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the measuring input for a workpiece probe.<br />
0 = Measuring input 1 is activated<br />
1 = Measuring input 2 is activated<br />
9751 CMM_MEAS_T_PROBE_INPUT<br />
MD number Measuring input for tool probe<br />
Default setting: 1 Min. input limit: 0 Max. input limit: 1<br />
Change applies from: IMMEDIATE Protection level: 3/4 Unit: -<br />
Data type: BOOL Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the measuring input for a tool probe.<br />
0 = Measuring input 1 is activated<br />
1 = Measuring input 2 is activated<br />
10-152<br />
12.01<br />
9752 CMM_MEASURING_DISTANCE<br />
MD number Maximum measurement path (before and after the measuring point) for automatic<br />
measurement in the program.<br />
Default setting: 5 Min. input limit: 0.01 Max. input limit: 1000<br />
Change applies from: IMMEDIATE Protection level: 3/4 Unit: mm<br />
Data type: DOUBLE Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the maximum measurement path for “Tool measurement” before and after<br />
the expected switching position (workpiece edge) and applies for automatic programmed<br />
measurements. If no switching signal is output within the area, the error message “probe<br />
does not switch” is output.<br />
9753 CMM_MEAS_DIST_MAN<br />
MD number Maximum measurement path for manual measurement (before and after the measuring<br />
point)<br />
Default setting: 10 Min. input limit: 0.01 Max. input limit: 1000<br />
Change applies from: IMMEDIATE Protection level: 3/4 Unit: mm<br />
Data type: DOUBLE Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the maximum measurement path for “Tool measurement” for manual<br />
mode before and after the expected switching position (workpiece edge). If no switching<br />
signal is output within the area, the error message “probe does not switch” is output.<br />
9754 CMM_MEAS_DIST_TOOL_LENGTH<br />
MD number Maximum measurement path for tool length (before and after measuring point)<br />
Default setting: 2 Min. input limit: 0.001 Max. input limit: 1000<br />
Change applies from: IMMEDIATE Protection level: 3/4 Unit: mm<br />
Data type: DOUBLE Valid as of SW:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the maximum measurement path for “Tool measurement” for measuring<br />
the tool length of a rotating spindle before and after the expected switching position (tool<br />
length). If no switching signal is output within the area, the error message “probe does not<br />
switch” is output.<br />