12.01<br />

4.3 Overview of blocks<br />

4.3.1 Function blocks<br />

The following list shows the function blocks used by <strong>ShopMill</strong>.<br />

Table 4-1 Function blocks for <strong>ShopMill</strong><br />

E Siemens AG, 2001. All rights reserved<br />

<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />

4PLCProgram<br />

4.3 Overview of blocks<br />

Block Comment<br />

FC30 <strong>ShopMill</strong> PLC program; is called in OB1.<br />

FC31 -33 <strong>ShopMill</strong> PLC program; are only loaded.<br />

FC34 Diagnostics block for monitoring the standard interface signals written<br />

by the <strong>ShopMill</strong> PLC program; can be called for diagnostics purposes<br />

in OB1.<br />

FC35 <strong>ShopMill</strong> PLC program; is only loaded.<br />

FC90 Supplies the <strong>ShopMill</strong> interface DB82; can be called in OB1.<br />

FC100 Sample block for the configuration of tool management<br />

function; called in OB100.<br />

FB20 HiGraphErrEmitterFB block for errors and monitoring time; is only<br />

loaded.<br />

FB110 Sample block for transfer of tool management data; called in OB1.<br />

Note<br />

S The numbers of the function blocks FC30--35 must not be changed. This<br />

means that the blocks with these numbers already allocated by the user<br />

program must be changed.<br />

S Block FB20 is loaded only. It must be available in the automation system<br />

(AS) during operation. A block call is not required.<br />

S The blocks for tool management are described in Chapter 9 “Tool Management”.<br />

When using the tool management on a machine for the first time,<br />

please note that the tool management uses data blocks DB71--DB74; these<br />

data blocks cannot be assigned by the user PLC basic program.<br />