6Machine Data<br />
6.2 Display machine data for <strong>ShopMill</strong><br />
6.2.2 Description of display machine data<br />
9478 $MM_TO_OPTION_MASK<br />
MD number Settings for <strong>ShopMill</strong><br />
Default setting: 1 Min. input limit: 0000 Max. input limit: FFFF<br />
Changes valid from: POWER ON Protection level: 1 Unit: Hex<br />
Data type: LONG Valid as of software version:<br />
<strong>840D</strong> SW 6.2, <strong>810D</strong> SW 4.2<br />
Meaning: Bit0: Input extensions for <strong>ShopMill</strong> (cooling water, etc.)<br />
Bit1: Reserved<br />
Bit2: Reserved<br />
Bit3: Creation of new tools directly in a magazine location not allowed<br />
Bit4: Reserved<br />
Bit5: Reserved<br />
Bit6: Reserved<br />
Bit7: Input disable for loaded tools (wear data excepted)<br />
Bit8: Evaluate file to_mill.ini<br />
Bit9: No loading/unloading when program is running<br />
Bit10: Compute tool wear inputs additively<br />
Bit11: Spare<br />
9600 $MM_CTM_SIMULATION_DEF_X<br />
MD number Simulation of default value X<br />
Default setting: 0 Min. input limit: -10000 Max. input limit: 10000<br />
Changes valid from: POWER ON Protection level: 3/4 Unit: mm<br />
Data type: LONG Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the size of the X coordinate of the display area. When you press softkey<br />
TO ORIGIN in simulation mode, you will go to the value set in this MD.<br />
Corresponding to ... MD 9601 $MM_CTM_SIMULATION_DEF_Y<br />
MD 9602 $MM_CTM_SIMULATION_DEF_VIS_AREA<br />
9601 $MM_CTM_SIMULATION_DEF_Y<br />
MD number Simulation of default value Y<br />
Default setting: 0 Min. input limit: -10000 Max. input limit: 10000<br />
Changes valid from: POWER ON Protection level: 3/4 Unit: mm<br />
Data type: LONG Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the size of the Y coordinate of the display area. When you press softkey<br />
TO ORIGIN in simulation mode, you will go to the value set in this MD.<br />
Corresponding to ... MD 9600 $MM_CTM_SIMULATION_DEF_X<br />
MD 9602 $MM_CTM_SIMULATION_DEF_VIS_AREA<br />
6-74<br />
12.01<br />
E Siemens AG, 2001. All rights reserved<br />
<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition