12.01<br />

12.4 Machine data for protection levels<br />

Lockable<br />

data areas<br />

Default setting<br />

E Siemens AG, 2001. All rights reserved<br />

<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />

12 Access Protection via Password and Keyswitch<br />

12.4 Machine data for protection levels<br />

The machine manufacturer or end user can set MMC machine data to assign<br />

the appropriate protection levels to individual functions and data areas. For a<br />

number of data types, it is possible to input different protection levels for read<br />

and write access authority.<br />

The machine data which can be “locked” by means of protection levels in<br />

<strong>ShopMill</strong> are listed below:<br />

Operator panel machine data Access to<br />

9182 USER_CLASS_INCH_METRIC Inch/metric switchover<br />

9200 USER_CLASS_READ_TOA Read tool offsets<br />

9201 USER_CLASS_WRITE_TOA_GEO Write tool geometry<br />

(including type and tool edge)<br />

9202 USER_CLASS_WRITE_TOA_WEAR Write tool wear (without<br />

limit value)<br />

9210 USER_CLASS_WRITE_ZOA Write settable zero<br />

offsets<br />

9215 USER_CLASS_WRITE_SEA Write setting data<br />

9217 USER_CLASS_WRITE_PROGRAM Write/edit part programs<br />

9218 USER_CLASS_SELECT_PROGRAM Enable program selection<br />

9222 USER_CLASS_WRITE_RPA Write R parameters<br />

9252 USER_CLASS_TM_SKTOOLLOAD Enable tool load<br />

9253 USER_CLASS_TM_SKTOOLUNLOAD Enable tool unload<br />

9258 USER_CLASS_TM_SKNCNEWTOOL Enable create a new tool<br />

9259 USER_CLASS_TM_SKNCDELTOOL Enable delete a tool<br />

These machine data are assigned protection level 7 per default during the standard<br />

start-up procedure. All these data areas and functions can thus be<br />

accessed and altered in keyswitch position 0.<br />

The protection level defaults may need to be changed by the machine manufacturer<br />

or end user. They can also be set to protection levels 0 to 3.<br />