12.01<br />
12.4 Machine data for protection levels<br />
Lockable<br />
data areas<br />
Default setting<br />
E Siemens AG, 2001. All rights reserved<br />
<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />
12 Access Protection via Password and Keyswitch<br />
12.4 Machine data for protection levels<br />
The machine manufacturer or end user can set MMC machine data to assign<br />
the appropriate protection levels to individual functions and data areas. For a<br />
number of data types, it is possible to input different protection levels for read<br />
and write access authority.<br />
The machine data which can be “locked” by means of protection levels in<br />
<strong>ShopMill</strong> are listed below:<br />
Operator panel machine data Access to<br />
9182 USER_CLASS_INCH_METRIC Inch/metric switchover<br />
9200 USER_CLASS_READ_TOA Read tool offsets<br />
9201 USER_CLASS_WRITE_TOA_GEO Write tool geometry<br />
(including type and tool edge)<br />
9202 USER_CLASS_WRITE_TOA_WEAR Write tool wear (without<br />
limit value)<br />
9210 USER_CLASS_WRITE_ZOA Write settable zero<br />
offsets<br />
9215 USER_CLASS_WRITE_SEA Write setting data<br />
9217 USER_CLASS_WRITE_PROGRAM Write/edit part programs<br />
9218 USER_CLASS_SELECT_PROGRAM Enable program selection<br />
9222 USER_CLASS_WRITE_RPA Write R parameters<br />
9252 USER_CLASS_TM_SKTOOLLOAD Enable tool load<br />
9253 USER_CLASS_TM_SKTOOLUNLOAD Enable tool unload<br />
9258 USER_CLASS_TM_SKNCNEWTOOL Enable create a new tool<br />
9259 USER_CLASS_TM_SKNCDELTOOL Enable delete a tool<br />
These machine data are assigned protection level 7 per default during the standard<br />
start-up procedure. All these data areas and functions can thus be<br />
accessed and altered in keyswitch position 0.<br />
The protection level defaults may need to be changed by the machine manufacturer<br />
or end user. They can also be set to protection levels 0 to 3.<br />
J<br />
12-165