12.01<br />
Example<br />
Procedure<br />
E Siemens AG, 2001. All rights reserved<br />
<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition<br />
8 Tools<br />
8.5 Modify texts for tool-specific functions<br />
The cursor text “Tool-spec. function 1” in the tool list should be changed to ”Air<br />
cooling”.<br />
You must make the following entry in file ”aluc.txt”:<br />
89911 0 0 ”Air cooling”<br />
The two parameters 2 and 3 separated by blanks are control characters for text<br />
output and must always be set to 0.<br />
To select file aluc.txt, proceed as follows:<br />
S Switch to the subdirectory ...\instutil in the application environment.<br />
S Call the APP_INST program.<br />
S Select ”Modify configuration”.<br />
S Specify whether the texts for the 1st or 2nd language are to be edited:<br />
”Edit text files for first language” or<br />
”Edit text files for second language”.<br />
S Scroll through the menu until the option ”alarm texts for user cycles”<br />
appears and then enter the corresponding number.<br />
This opens the text file ALUC.TXT with the DOS editor ”edit”.<br />
S Enter the texts of your choice.<br />
S Save the file and close the editor.<br />
S Press the ”ESC” key twice.<br />
The text modifications become operative when you take the following steps:<br />
S Select ”Install all modules on hardware”.<br />
S Confirm your language selection with “F4 Accept”.<br />
S Select ”Create Flash Memory Card image”.<br />
S Specify the source drive for the system disks.<br />
S Specify the target path for the system disks.<br />
S Enter the target drive to which the file must be saved.<br />
S Specify the target path for the file.<br />
S Use SINUCOPY to create a PC card (see Subsection 2.2.1 Start-up on a<br />
PCU 20).<br />
S Load the PC card contents to the control (see Subsection 2.2.1 Start-up on<br />
a PCU 20).<br />