6Machine Data<br />
6.2 Display machine data for <strong>ShopMill</strong><br />
6-78<br />
12.01<br />
9652 $MM_CMM_TOOL_LIFE_CONTROL<br />
MD number Tool monitoring<br />
Default setting: 1 Min. input limit: 0 Max. input limit: 1<br />
Changes valid from: POWER ON Protection level: 3/4 Unit: -<br />
Data type: BYTE Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD activates the tool monitoring. The tool monitoring function monitors the tool life and<br />
tool loading operations:<br />
0=Tool monitoring is not displayed<br />
1=Tool monitoring is displayed<br />
9653 $MM_CMM_ENABLE_A_AXIS<br />
MD number Enabling 4th axis for user interface<br />
Default setting: 0 Min. input limit: 0 Max. input limit: 3<br />
Changes valid from: IMMEDIATE Protection level: 3/4 Unit: -<br />
Data type: BYTE Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: Enable 4th axis (e.g. A axis) for user interface:<br />
0 = 4th axis is not displayed on the user interface<br />
1 = 4th axis is displayed on the user interface<br />
2 = 4th axis is displayed on the user interface and can be programmed<br />
3 = 4th axis is displayed on the user interface only for reference point approach<br />
9654 $MM_CMM_SPEED_FIELD_DISPLAY_RES<br />
MD number Number of decimal places in the speed input field<br />
Default setting: 0 Min. input limit: 0 Max. input limit: 4<br />
Changes valid from: IMMEDIATE Protection level: 3/4 Unit: -<br />
Data type: BYTE Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD is for defining the number of decimal places in parameter field S (speed).<br />
9655 $MM_CMM_CYC_PECKING_DIST<br />
MD number Lifting amount for deep hole drilling<br />
Default setting: 1.0 Min. input limit: 0.0 Max. input limit: 100.0<br />
Changes valid from: IMMEDIATE Protection level: 3/4 Unit: mm<br />
Data type: DOUBLE Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the retraction distance for deep hole drilling with chip break.<br />
9656 $MM_CMM_CYC_DRILL_RELEASE_DIST<br />
MD number Lifting amount for boring<br />
Default setting: 0.1 Min. input limit: -1 Max. input limit: 10.0<br />
Changes valid from: IMMEDIATE Protection level: 3/4 Unit: mm<br />
Data type: DOUBLE Valid as of software version:<br />
<strong>840D</strong> SW 4.3, <strong>810D</strong> SW 2.3<br />
Meaning: This MD defines the clearance distance traveled by the tool in the X direction during hole<br />
boring operations.<br />
Note:<br />
-1 means that the value of the retraction distance D can be entered in the operator<br />
interface.<br />
E Siemens AG, 2001. All rights reserved<br />
<strong>SINUMERIK</strong> <strong>840D</strong>/<strong>810D</strong> Description of Functions <strong>ShopMill</strong> (FBSP) - 12.01 Edition