<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />

reset, but it happens only if no data can be received from <strong>STEPP</strong><br />

device via data connection. The countdown starts after receiving<br />

“Connect 9600 ...” and no data can be transmitted.<br />

- The entry in field (21) will be the operation’s time of GSM core. If<br />

the entered time in minutes runs out the GPS core per<strong>for</strong>ms a reset,<br />

but it only happens if no satellites are in view. This procedure<br />

repeats itself until the acquisition of satellites <strong>for</strong> a GPS fix is<br />

successful.<br />

4.2.3.1.2 Alarm key configuration<br />

Image 10: <strong>Configuration</strong> of alarm keys<br />

Entry Description<br />

Key1 (1) Alarm input 1<br />

Key2 (1) Alarm input 2<br />

Key3 (1) Alarm input 3<br />

Key4 (1) Alarm input 4<br />

IGN (1) Alarm input IGNITION<br />

BAT (1) Alarm input BATTERY<br />

Phone number (2)<br />

Entry of target telephone number <strong>for</strong> the respective<br />

alarm message.<br />

Alarm text (3) Entry of alarm text <strong>for</strong> the respective alarm message.<br />

Protocol/type (4)<br />

Send (5)<br />

Entry of the alarm type <strong>for</strong> the respective alarm<br />

message. Please read the chapter <strong>Configuration</strong> of<br />

alarm inputs.<br />

Saves the configuration of the respective alarm<br />

entries in <strong>Falcom</strong> <strong>STEPP</strong><br />

Table 7: <strong>Configuration</strong> of alarm inputs<br />

This chapter explains the configuration of one of the most important functions<br />

of the <strong>Falcom</strong> <strong>STEPP</strong>: the alarm input configuration.<br />

The required command (<strong>for</strong> a directly connected <strong>Falcom</strong> <strong>STEPP</strong>) is:<br />

$PSRF108,KEY[1..8]=target telephone number,alarm text,Flag*15<br />

The parameters have the following meaning:<br />

• KEY[1..8] denotes the respective alarm input<br />

This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />