14.11.2012 Views

6 Configuration commands - for Falcom STEPP

6 Configuration commands - for Falcom STEPP

6 Configuration commands - for Falcom STEPP

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />

SMS<br />

command<br />

NMEA<br />

message<br />

6.3.10 LOG<br />

How the parameter could be sent:<br />

&CNF UNIT VOL=10,12<br />

$PSRF108,VOL=10,12*44<br />

Syntax LOG=,,,,,,<br />

SMS<br />

command<br />

NMEA<br />

message<br />

Configuring triggers specifies to the <strong>STEPP</strong> device under what<br />

circumstances a position should be logged to memory. This parameter<br />

allows you to specify/modify the parameters of the history data. The history<br />

logging depends on the view satellites and the minimum or maximum time,<br />

distance and speed. If all minimum values or just one maximum value is<br />

exceeded, then the <strong>STEPP</strong> begins storing the NMEA protocols in the<br />

history.<br />

Once all parameters required <strong>for</strong> the new configuration have been specified,<br />

transfered (via SMS or locally) and accepted from the device, the <strong>STEPP</strong><br />

begins to implement the parameters.<br />

New configurations take effect immediately, so they become permanently<br />

enabled until changed.<br />

<br />

It determines the minimum number of in view satellites able to start<br />

the history logging.<br />

<br />

It specifies the minimum time. The unit is second [s]<br />

<br />

It specifies the maximum time. The unit is second [s]<br />

<br />

It specifies the minimum distance. The unit is meter [m]<br />

<br />

It specifies the maximum distance. The unit is meter [m]<br />

<br />

It specifies the minimum speed. The unit is kilometer per hour [km/h]<br />

<br />

It specifies the maximum speed. The unit is kilometer per hour [km/h]<br />

How this command could be sent:<br />

&CNF UNIT LOG=4,5,3600,0,0,0,0<br />

$PSRF108,LOG=4,5,3600,0,0,0,0*7F<br />

Notes<br />

• To understand and to set properly the ,, and<br />

, , and parameters, please, refer to the<br />

chapter 5.1.2. In that chapter you will find detailed in<strong>for</strong>mation.<br />