<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />
Logs every second at<br />
speed ≥ 40 km/h<br />
Table 21: Programming example<br />
Examples of history configuration<br />
0 0 0 0 0 40<br />
Below are some configuration examples, which can be entered directly in the<br />
configuration tool.<br />
Example 1<br />
� Record every 50 m if the vehicle has a speed less then 25 km/h<br />
� Record every 2 sec. if the vehicle is moving at a speed between 25 and<br />
50 km/h<br />
� Record every second if the vehicle is driving faster than 50 km/h<br />
FixMin<br />
Time [s]<br />
FixMax<br />
Time [s]<br />
Dist.Min<br />
[m]<br />
Dist.Max<br />
[m]<br />
SpeedMin<br />
[km/h]<br />
Speed<br />
Max [km/h]<br />
Example 1, settings 2 0 0 50 25 50<br />
SMS command &CNF [PWD] UNIT MSG=S132345678,4,2,0,0,50,25,50,RMCIOP<br />
NMEA message $PSRF108,LOG=4,2,0,0,50,25,50*7A<br />
Example 2<br />
� Record every 50m if the vehicle is driving faster than 25 km/h<br />
FixMin<br />
Time [s]<br />
FixMax<br />
Time [s]<br />
Dist.Min<br />
[m]<br />
Dist.Max<br />
[m]<br />
SpeedMin<br />
[km/h]<br />
Speed<br />
Max [km/h]<br />
Example 2, settings 0 0 50 0 25 0<br />
SMS command &CNF [PWD] UNIT MSG=S132345678,4,0,0,50,0,25,0,RMCIOP<br />
NMEA message $PSRF108,LOG=4,0,0,50,0,25,0*4D<br />