6 Configuration commands - for Falcom STEPP
6 Configuration commands - for Falcom STEPP
6 Configuration commands - for Falcom STEPP
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />
• Minimum value denotes the minimum value, which is to be entered. In our<br />
software application the value has to be ≥ 1.0. See example below.<br />
• Maximum value denotes the maximum value, which is to be entered. In<br />
our software application the value has to be ≤ 5.0. See example below.<br />
• Protocol/type denotes the type of alarm to be sent.<br />
The following alarm types can be distinguished:<br />
� SMS and GPIOP – A SMS is sent to the target telephone number<br />
containing the alarm text with attached $GPIOP protocol.<br />
� SMS and GPGGA<br />
An SMS is sent to the target telephone number containing the alarm<br />
text with attached $GPGGA protocol<br />
� SMS and GPRMC<br />
An SMS is sent to the target telephone number containing the alarm<br />
text with attached $GPRMC protocol<br />
� SMS and GPGSV<br />
An SMS is sent to the target telephone number containing the alarm<br />
text with attached $GPGSV protocol<br />
� SMS and GPGSA<br />
An SMS is sent to the target telephone number containing the alarm<br />
text with attached $GPGSA protocol<br />
� SMS and GPGLL<br />
An SMS is sent to the target telephone number containing the alarm<br />
text with attached $GPGLL protocol<br />
� Voice call<br />
A voice call is created <strong>for</strong> the target telephone number<br />
� Alarm call<br />
An alarm call is created <strong>for</strong> the target telephone number<br />
(Loudspeaker in the vehicle is deactivated – only the microphone is<br />
active)<br />
� Data call<br />
A data call is created <strong>for</strong> the target telephone number and the defined<br />
GPS protocols are transmitted<br />
� Clear key<br />
The configuration of the active alarm input is erased. An alarm<br />
notification will no longer take place via this alarm entry.<br />
EXAMPLE <strong>for</strong> analogue input 1:<br />
Min. value is : 2.0 (V)<br />
Max. value is : 3.0 (V)<br />
That means the user has chosen the range of value from 2.0 (V) to 3.0 (V).<br />
If the installed analogue device leaves the pre-defined range (up or down),<br />
the FALCOM <strong>STEPP</strong> will send an SMS (entered in the alarm text input<br />
field) to the target telephone number (01234567). In case that value comes<br />
back to the pre-defined range (from 2.0 to 3.0 (V)), the FALCOM <strong>STEPP</strong><br />
does not send SMS to the target telephone number. An SMS alarm will be<br />
sent to the target telephone number only in case of exceeding or falling<br />
below the entered range.<br />
In case of an alarm configuration on analogue input 1 or 2, user can select<br />
not only a SMS message, but he also can attach a GPS message (e.g.<br />
GPRMC protocol) to the SMS text.<br />
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />
Page 40