<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />
SMS<br />
command<br />
NMEA<br />
message<br />
How the parameter could be sent:<br />
&CNF UNIT TEL0=S+49123456<br />
&CNF UNIT TEL1=V+49123457<br />
&CNF UNIT TEL2=A+49123458<br />
&CNF UNIT TEL3=D+49123459<br />
&CNF UNIT TEL3<br />
$PSRF108,TEL0=S+49123456*20<br />
$PSRF108,TEL1=V+49123457*25<br />
$PSRF108,TEL2=A+49123458*3E<br />
$PSRF108,TEL3=D+49123459*3B<br />
$PSRF108,TEL3*6C<br />
Notes<br />
• If you define at least one phone number into the authorised list, the<br />
access permissions are allowed only <strong>for</strong> that number(s) (i.e. except the<br />
authorised persons, no other person can access the <strong>STEPP</strong> device)<br />
• The access permissions are allowed <strong>for</strong> all users, if the authorised list is<br />
empty (i.e. unspecified persons who knows the phone number of the<br />
<strong>STEPP</strong> can access it).<br />
• Using the entry type the <strong>STEPP</strong> can establish different call types.<br />
• The <strong>STEPP</strong> allways compares the caller number with the number(s)<br />
stored in the autorized list, and if no identical numbers are found, calls<br />
could not be established.<br />
• If caller number is identical to one of the numbers stored in the<br />
autorized list, however the types are different, <strong>for</strong> example, the<br />
type of stored phone number is S (specified <strong>for</strong> SMS) and caller<br />
connection is a Voice, Data or Alarm type, the call could not be<br />
established. <strong>STEPP</strong> hangs-up that call and sends to the caller a SMS<br />
including GPS protocols.<br />
• If type connection is not specified, the number<br />
will be available only <strong>for</strong> Data call (default setting).<br />
• To delete a phone number from the authorised list, a SMS command<br />
without value has to be sent to the device.<br />
6.3.9 VOL<br />
Syntax VOL=,<br />
This parameter allows you to adjust the loudspeaker and microphone<br />
volume levels. The values of the volume can be specified by entering one of<br />
the supported values in range of 0 to 15.<br />
:<br />
The speaker level value can be defined from 0 (silent) to 15 (loudest).<br />
:<br />
The microphone level value can be defined from 0 (silent) to 15<br />
(loudest).<br />