<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />

SMS<br />

command<br />

NMEA<br />

message<br />

How the parameter could be sent:<br />

&CNF UNIT TEL0=S+49123456<br />

&CNF UNIT TEL1=V+49123457<br />

&CNF UNIT TEL2=A+49123458<br />

&CNF UNIT TEL3=D+49123459<br />

&CNF UNIT TEL3<br />

$PSRF108,TEL0=S+49123456*20<br />

$PSRF108,TEL1=V+49123457*25<br />

$PSRF108,TEL2=A+49123458*3E<br />

$PSRF108,TEL3=D+49123459*3B<br />

$PSRF108,TEL3*6C<br />

Notes<br />

• If you define at least one phone number into the authorised list, the<br />

access permissions are allowed only <strong>for</strong> that number(s) (i.e. except the<br />

authorised persons, no other person can access the <strong>STEPP</strong> device)<br />

• The access permissions are allowed <strong>for</strong> all users, if the authorised list is<br />

empty (i.e. unspecified persons who knows the phone number of the<br />

<strong>STEPP</strong> can access it).<br />

• Using the entry type the <strong>STEPP</strong> can establish different call types.<br />

• The <strong>STEPP</strong> allways compares the caller number with the number(s)<br />

stored in the autorized list, and if no identical numbers are found, calls<br />

could not be established.<br />

• If caller number is identical to one of the numbers stored in the<br />

autorized list, however the types are different, <strong>for</strong> example, the<br />

type of stored phone number is S (specified <strong>for</strong> SMS) and caller<br />

connection is a Voice, Data or Alarm type, the call could not be<br />

established. <strong>STEPP</strong> hangs-up that call and sends to the caller a SMS<br />

including GPS protocols.<br />

• If type connection is not specified, the number<br />

will be available only <strong>for</strong> Data call (default setting).<br />

• To delete a phone number from the authorised list, a SMS command<br />

without value has to be sent to the device.<br />

6.3.9 VOL<br />

Syntax VOL=,<br />

This parameter allows you to adjust the loudspeaker and microphone<br />

volume levels. The values of the volume can be specified by entering one of<br />

the supported values in range of 0 to 15.<br />

:<br />

The speaker level value can be defined from 0 (silent) to 15 (loudest).<br />

:<br />

The microphone level value can be defined from 0 (silent) to 15<br />

(loudest).<br />