14.11.2012 Views

6 Configuration commands - for Falcom STEPP

6 Configuration commands - for Falcom STEPP

6 Configuration commands - for Falcom STEPP

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />

[<strong>Falcom</strong><strong>STEPP</strong>-History-File generated: 1/28/2003]<br />

Position1=$GPGGA,095150.000,5040.4014,N,01058.8657,E,1,04,1.0,494.6,M,,,,0000*0D<br />

Position2=$GPRMC,095150.000,A,5040.4014,N,01058.8657,E,,,280103,,*03<br />

Position3=$GPGGA,095200.000,5040.4014,N,01058.8657,E,1,04,1.0,494.6,M,,,,0000*0B<br />

Position4=$GPRMC,095200.000,A,5040.4014,N,01058.8657,E,,,280103,,*05<br />

Position5=$GPGGA,095210.000,5040.4014,N,01058.8657,E,1,04,1.0,494.6,M,,,,0000*0A<br />

“Alarm.log”-File<br />

When an alarm SMS is received, <strong>STEPP</strong>config will create this file with an<br />

attached GPS position.<br />

The file has the following <strong>for</strong>mat:<br />

[SMSalarms]<br />

1/9/2003 10:27:36<br />

AM=$GPGGA,092648.343,5040.3946,N,01058.8645,E,1,06,1.5,487.4,M,,,,0000<br />

1/9/2003 10:40:18<br />

AM=$GPGGA,093930.058,5040.3968,N,01058.8613,E,1,07,1.3,488.0,M,,,,0000<br />

1/9/2003 1:28:07<br />

PM=$GPGGA,122718.903,5040.3980,N,01058.8646,E,1,06,1.3,494.3,M,,,,0000<br />

To send a saved log file via the serial port to a map software, please<br />

proceed as follows:<br />

1. Click on the “read logfile” button (7), and from the subsequent<br />

dialogue box, choose the log file to be sent.<br />

The data sets contained in the file will display in the terminal<br />

window (1), and the number of data sets in the file will display in the<br />

field “records” (4).<br />

2. Click on the “send logfile” button (8) to send the log file to the COM<br />

port as defined under “Settings” (see chapter 3.2.1.2).<br />

You can cancel the task any time by clicking on “cancel” (9).<br />

If you double-click on one of the data sets shown in the terminal<br />

window (1), any previously started transfer will be terminated and<br />

the chosen data set sent to the serial port.<br />

3. Exit closes the “History Tool” window<br />

4.3.6 Alarms window<br />