6 Configuration commands - for Falcom STEPP
6 Configuration commands - for Falcom STEPP
6 Configuration commands - for Falcom STEPP
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>STEPP</strong>CONFIG VERSION 1.8.14<br />
Example 3<br />
� Record every 2 sec. if the vehicle is moving at a speed between 25 and<br />
50 km/h<br />
FixMin<br />
Time [s]<br />
FixMax<br />
Time [s]<br />
Dist.Min<br />
[m]<br />
Dist.Max<br />
[m]<br />
SpeedMin<br />
[km/h]<br />
Speed<br />
Max [km/h]<br />
Example 3, settings 2 0 0 0 25 50<br />
SMS command &CNF [PWD] UNIT MSG=S132345678,4,2,0,0,0,25,50,RMCIOP<br />
NMEA message $PSRF108,LOG=4,2,0,0,0,25,50*4F<br />
Example 4<br />
� Record every second if the vehicle is driving faster than 50 km/h<br />
FixMin<br />
Time [s]<br />
FixMax<br />
Time [s]<br />
Dist.Min<br />
[m]<br />
Dist.Max<br />
[m]<br />
SpeedMin<br />
[km/h]<br />
Speed<br />
Max [km/h]<br />
Example 4, settings 0 0 0 0 0 50<br />
SMS command &CNF [PWD] UNIT MSG=S132345678,4,0,0,0,0,0,50,RMCIOP<br />
NMEA message $PSRF108,LOG=4,0,0,0,0,0,50*7A<br />
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />
Page 69