I/32 System Input BoardsFigure 6-8: apC Event Dialog Box• When the panel is in Communications Failure:– Enter an event that will be activated when a communications failureoccurs on this port. Double-click on this text box to display aselection browser for events.• When the panel is Full:– Enter an event to activate when the panel is full and cannot acceptadditional cardholder records. Double-click on this text box todisplay an Event Selection dialog box for a list of specific events.• When the panel is nearly full (has reached a user-defined percent ofcapacity).– Enter an event to activate when the panel exceeds the capacity-usedthreshold specified in the next field. Double-click on this text box todisplay an Event Selection dialog box for a list of specific events.NOTEThe system determines the “nearly full” capacity by estimating themaximum number of cardholder records on the panel.6–8 C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Hardware</strong> <strong>Configuration</strong> <strong>Guide</strong>