Configuring iSTAR Classic & iSTAR Pro ControllersTable 1-3: Controller Dialog Box Fields, continuedBox Field DescriptionIdentification, continued Online, continued If you delete a controller, it is ignored by the C•CURE <strong>800</strong>/<strong>800</strong>0host and cannot communicate with other cluster members.To stop a controller performing access control decisions:• Put any attached readers offline. (Do not put the controlleroffline until you put these objects offline.- or -• Erase the controller’s memory.iSTAR hardware Sub-typeDescriptionA read-only field displaying the controller sub-type: iSTAR Pro/Classic or iSTAR eX.Enter a general comment about the controller. This text is forinformation only.General TabThis controller isin clusterThe controller is in timezone:Displays whether this controller is the cluster master or acluster member. Use the Cluster dialog box to specify amaster for a cluster. You cannot edit this field.Displays the name of the cluster to which this controller isassigned. Use the Cluster dialog box to add controllers toclusters. You cannot edit this field.Specify a time zone for the controller. Double-click on this boxto display a selection browser for time zones.The following objects are associated with the controller’s timezone:• Inputs, outputs, and readers on the controller.• Doors and door groups with inputs, outputs, or readers onthe controller.• Elevators and elevator groups with inputs, outputs, orreaders on the controller.NOTE: Only time specifications and clearances that use thesame time zone as the controller are downloaded tothe controller. If you change the controller’s time zoneafter a time specification or clearance has beendownloaded to the controller, a matching violationoccurs. The time zone is downloaded to the controller,and the clearance is deleted from the controller. Seethe C•CURE <strong>800</strong>/<strong>800</strong>0 Software <strong>Configuration</strong> <strong>Guide</strong>for more information.C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Hardware</strong> <strong>Configuration</strong> <strong>Guide</strong> 1–15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!