10.07.2015 Views

C•CURE 800/8000 Hardware Configuration Guide - Tyco Security ...

C•CURE 800/8000 Hardware Configuration Guide - Tyco Security ...

C•CURE 800/8000 Hardware Configuration Guide - Tyco Security ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Main Board TabTable 2-4: Main Board Tab FieldsBox Field/Button DescriptionInputs Tamper Click this check box to configure the Tamper input. TheTamper input activates when the controller cabinet is opened orremoved from its mounting surface.The system automaticallyconfigures the input using the values from the default inputdefinition. To view or edit the input, click the input’s Viewbutton. See “Configuring Inputs” on page 5-2 for moreinformation.If Online is the default setting for the input and you do notdeselect this option in the Input dialog box, the input is setonline and downloaded after you click OK in the Controllerdialog box.Deselecting the Tamper check box in the Controller dialogbox, deletes the Tamper input.AC power fail inputLow battery inputClick this check box to configure the AC powerfail input. ACpower fail input monitors the AC power failure output of abattery backup unit. When this alarm input activates, itspecifies that the iSTAR eX has lost its primary power sourceand is operating on batteries. The system automaticallyconfigures the input using the values from the default inputdefinition. To view or edit the input, click the input’s Viewbutton. See “Configuring Inputs” on page 5-2 for moreinformation.If Online is the default setting for the input and you do notdeselect this option in the Input dialog box, the input is setonline and downloaded after you click OK in the Controllerdialog box.Deselecting the AC power fail input check box in theController dialog box, deletes the AC powerfail input.Click this check box to configure the Low Battery input. Lowbattery input activates when the emergency battery is runninglow on power. The system automatically configures the inputusing the values from the default input definition. To view oredit the input, click the input’s View button. See “ConfiguringInputs” on page 5-2 for more information.If Online is the default setting for the input and you do notdeselect this option in the Input dialog box, the input is setonline and downloaded after you click OK in the Controllerdialog box.Deselecting the Low Battery input check box in theController dialog box, deletes the Low Battery input.C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Hardware</strong> <strong>Configuration</strong> <strong>Guide</strong> 2–21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!