apC Dialup Overview• Each input can activate at most one output (or output group) on thepanel, and each output can be activated by at most one input on thepanel• Time specifications can only activate events that activate and pulseoutputs, arm inputs, unlock doors, and cause readers to require PINs.However, if one of the following options is configured for the event, theevent actions are not performed: the event requires acknowledgement,an activation delay or a minimum activation time has been specified, orthe time zone of the time specification triggering the event is differentfrom the time zone of the object on which the action is being performed.• Time specifications that require PINs can be downloaded from theReader keypad configuration dialog box.• Either the host or panel can establish a telephone connection. Thefollowing sections describe the conditions that cause the host to dial thepanel, and the panel to dial the host.Dialing Out to PanelsThe host dials the panel and downloads information under the followingconditions:• Periodic and Dial Out The C•CURE <strong>800</strong>/<strong>800</strong>0 provides two dialoutconfigurations that you can use to specify when the host dials panels. UsePeriodic to specify that configuration changes and cardholderinformation are periodically downloaded to panels, and activity isuploaded to the host from the panel. Use Dial Out to specify thatconfiguration changes are automatically downloaded to panels within aspecified time. See “Configuring Dial Out Options for Host and Panels”on page 9-13 and “Configuring Periodic Dial Out Options for Host andPanels” on page 9-16 for more information.• Manual actions at the Monitoring Station Users at the MonitoringStation can connect the host to dialup panels using the Connect manualaction on the apC dialog box. See the C•CURE <strong>800</strong>/<strong>800</strong>0 Monitoring Station<strong>Guide</strong> for more information.• Events You can configure actions for events that cause the host to connectto panels. See the C•CURE <strong>800</strong>/<strong>800</strong>0 Software <strong>Guide</strong> for more information.• State changes If a state change occurs for an object on the host and thepanel needs the information, the host dials the panel immediately.C•CURE <strong>800</strong>/<strong>800</strong>0 <strong>Hardware</strong> <strong>Configuration</strong> <strong>Guide</strong> 9–3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!