10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>TO</strong> <strong>35C2</strong>-3-445-2NAVY NAVFAC P-8-624-<strong>34</strong>(c)(d)(e)(f)Move the piston gradually towards the fully closed throttle position. The transducer secondaryvoltage, indicated by meter M1 shall increase in a linear manner to a maximum of 48 to 55 volts.Repeat these adjustments until the transducer secondary voltage increases linearly from the lowestpossible value to a maximum value over the entire 1.0 inch displacement of the piston.When final adjustment is made lock the transducer core in place with the transducer core setscrew.Remove the gages, meter, and power supplies.9. Installation and Final Adjustment.(1) Position actuator unit (14, figure 3-36) to install Iockwashers (13), and bolts (12).(2) If removed, install threaded rod (11), locknut (10), rod ends (9), screws (8) and nut (7)(3) Install bolt (6) and nut (5).(4) Connect hydraulic lines (4 and 3) and electrical connectors (2 and 1).(5) Refer to the Operator and Unit Maintenance Manual and fill the hydraulic tank.NOTELeave governor linkage loose to accommodate adjustments.(6) Place the generator set START-RUN- S<strong>TO</strong>P switch in the RUN position.CAUTIONDo not attempt to start the generator set. Failure to observe this caution could result inequipment damage.(7) Place the generator set BATTLE SHORT switch in the override (ON) position.(8) Beginning at the full counterclockwise position, rotate the fuel injection pump shutoff lever in theclockwise direction until a slight resistance is felt. Hold the shutoff lever in this position.NOTEThis resistance is the fuel injection pump governor linkage hook engaging the meteringvalve arm.(9) Move the hydraulic actuator unit piston to the extended position for 69-600-3, retracted position for69-600-2 (refer to table 3-2).(10) Adjust the hydraulic actuator governor linkage until it fits between the actuator unit piston clevis andthe fuel injection pump shutoff lever.(11) Return the generator set START-RUN-S<strong>TO</strong>P switch to the S<strong>TO</strong>P position and the BATTLE SHORTswitch to the OFF position.3-97

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!