10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>35C2</strong>-3-445-2NAVY NAVFAC P-8-624-<strong>34</strong>WARNINGSolvent, Dry Cleaning P-D-680, Type II is flammable and moderately toxic to skin,eyes and respiratory tract. Eye and skin protection required. Good general ventilationis normally adequate. Failure to observe this warning could result in servere personalinjury or death.(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)Clean special relay components with filtered compressed air and a soft bristle brush. If necessary,dirt deposits may be removed with a clean, lint–free cloth moistened with solvent P-D-680 Type II inparagraph 3-90c(1).Inspect potentiometer for cracked casing, corroded terminals and burns or other indication orshorting.Inspect wiring harness assembly for cracked or deteriorated insulation, damaged or loose connectorpins, and burned areas indicating shorting.Inspect protective caps for cracks, excessive wear, broken chain and other damage.Inspect components of DC relay assembly for cracks, burns, corrosion, and evidence of shorting oroverheating.Inspect instrument shunt for burns, corrosion, and evidence of shorting.Inspect special current transformer for corroded terminals and burns or other evidence of shorting.Inspect cranking relay K3 for cracked casing, corroded terminals, and evidence of shorting.Inspect terminal boards for cracks, burns, corroded terminals and terminal jumpers and otherdamage.Inspect resistor for burns, corroded terminals and other damage.Inspect chassis and cover for cracks, warping, and illegible markings.(12)(13)(a)(b)(c)(d)(14)(15)Check all threads for crossing, stripping, and peening.Using an ohmmeter, test potentiometer as follows:Connect ohmmeter leads between center terminal and either outer terminal.Slowly, at an even rate, rotate adjustment from full counterclockwise to full clockwise position.Ohmmeter indication shall change at an even rate from 0 to 12 ohms.Replace potentiometer if ohmmeter indicates discontinuity at any point or if rate of change iserratic.Test wiring harness assembly wires for continuity using figure 3-120 as a guide.If wiring, wiring harness has sustained damage and requires repair or rebuild, refer to figure 3-120for layout, identification and material requirements and Appendix A for detailed soldering andreplacement procedures.3-248

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!