<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>35C2</strong>-3-445-2NAVY NAVFAC P-8-624-<strong>34</strong>Table 3-7. Electric Governor Malfunction TestingPROBABLE CAUSE OFTERMINAL NORMAL NON-NORMAL READING CORRECTIVE ACTIONS 1.0 volt AC-RMS 1. Defective magnetic pickup.minimum while cranking. 2. Gap too large betweenmagnetic pickup and gearteeth.3. Improper or defective wiringto the magnetic pickup.KLN10.1±.20 volts DC while 1. DC power not connected orenergized (Internal low battery voltage.regulated D.C. supply). 2. Frequency trim potentiometershorted, grounded ormiswired.3. Wiring error.4. Defective control unit.Above 5.1 volts DC while 1. Frequency adjust set too low.running. (inverse speederror signal).2. Defective control unit.Above 5.1 volts is underspeed signal. Below 5.1volts is over speed signal.On speed will indicate asteady 5.1 volts.8.5 to 9.5 volts DC while 1. Battery voltage maybe toocranking. (Proportional low while cranking.actuator voltage). 2. Defective control unit.R 2.5 volts DC maximum 1. Output transistor open (defec–while cranking. (Tran- tive control unit).sister voltage).2. Defective actuator.3. Error in wiring to actuator.1. Replace magnetic pickup.2. Readjust magnetic pickup.3. Replace wiring harness.1. Connect DC power supply;replace DC battery.2. Replace control unit.3. Replace wiring harness.4. Replace control unit.1. Turn frequency adjustscrew clockwise.2. Replace control unit.1. Charge DC battery; replaceDC battery.2. Replace control unit.1. Replace control unit.2. Replace actuator.3. Replace wiring harness.NOTETwo people will be required to adjust the control unit. Ensure that the actuator linkagerod and all levers are securely fastened and move freely (without binding) beforeoperating the engine. Manually overcome the actuator until adjustment of the controlunit is completed and the governor is in control. Adjustment of the control unit will bemade with the engine operating in a no–load condition.(13)(14)Start the engine, manually operating the fuel shutoff lever.Turn the control unit frequency adjust screw clockwise until the proper engine speed is obtained.Several turns may be required. The generator set frequency adjust pot should now have sufficientadjustment travel to cause the generator set frequency meter to indicate beyond both of its extremelimits (388-412 Hz).3-190

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!