10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>TO</strong> <strong>35C2</strong>-445--2NAVY NAVFAC P-8-624-<strong>34</strong>Table 4-3. ELECTRICAL PERFORMANCE CHARACTERISTIC PARAMETERSAC PRECISE (CLASS 1) (CONTINUED)TEST METHODCHARACTERISTIC PARAMETER VALUE MIL-STD-705b. Frequency characteristics1. Regulation (%) 0.25 608.12. Steady–state-stability (variation (bandwidth %)(a) Short term (30 seconds) 0.5 608.1(b) Long term (4 hours) 1 608.23. Transient performance(a) Application of rated load(1) Undershoot (%) 1.5 608.1(2) Recovery (seconds) 1 608.1(b) Rejection of rated load(1) Overshoot (%) 1.5 608.1(2) Recovery (seconds) 1 608.14. Frequency adjustment range (Hz)(a) 50 Hz ±2 511.2(b) 60 Hz ±2 511.2(c) 400 Hz +20+20–10 511.2NOTE1. The voltage shall stabilize at or above this voltage.2. The generator set connected for three phase output and supplying a single phase, unity Power factorload connected line-to-line, with no other load on the set. The load current to be 25 percent of the ratedfull load current of the set.4-11. MALFUNCTION INDICA<strong>TO</strong>R TEST.a. The malfunction indicator system is electrically isolated and independent of the protection system. Testingof the indicators can be accomplished at the same time that the protective devices are tested in tests 6, 9, 10,11, 12, 14, 15, 16, 17 and 18 of table 4-1.b. In the event that one of the indicator circuits does not work, verify that the lamp is functional by operatingthe test and reset switch on the fault indicator panel.4-12. PHASE BALANCE TEST VOLTAGE.a. General. Polyphase electrical equipment may not operate properly or may be damaged if the phasevoltages of a polyphase generator differ greatly from each other. Also, large differences between the phasevoltages of a polyphase generator may be an indication that the generator set has been improperly manu–factured or damaged.b. Apparatus. A frequency meter (or tachometer as described and illustrated in MIL–HDBK–705. Method104, or 109.1 and an rms indicating ac voltmeter having an accuracy of ± 0.1% of the reading shall be requiredto perform both procedures. A means of separately exciting the generator is required since procedure II isperformed.4-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!