10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>TO</strong> <strong>35C2</strong>-3-445-2NAVY NAVFAC P-8-624-<strong>34</strong>5-3. HEATER CONTROL ASSEMBLY.a. Removal. Refer to the Operator and Unit Maintenance Manual for heater control assembly removalinstructions.b Disassembly.(1) Tag all electrical leads before disconnecting.(2) Remove screws (1, figure 5-1), and remove panel assembly (9), from housing (21).(3) Remove nut (2), tooth lockwasher (3), on-off switch (15), and key washer (11).(4) Remove nut (4), Iockwasher (5), and circuit breaker (16).(5) Remove lens (6), lamp (7), nut (8), lockwasher (10) and indicator light base (17) from panel (9).(6) Remove screw (13) from housing (14).(7) Remove nut (18), screw (19), and connector, from housing (21).c. Cleaning, Inspection, and Repair.WARNINGCompressed air used for cleaning and drying purposes can create airborne particlesthat may enter the eyes. Pressure shall not exceed 30 psig and use only with adequatechip guards and chipping goggles. Failure to observe this warning could result inserious personal injury or death.WARNINGSolvent, Dry Cleaning P–D-680, Type II is flammable and moderately toxic to skin,eyes and respiratory tract. Eye and skin protection required. Good general ventilationis normally adequate. Failure to observe this warning could result in serious personalinjury or death.(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)Clean all electrical parts with filtered compressed air and a soft bristle brush. If necessary, cakeddeposits may be removed with a clean, lint-free cloth moistened with solvent P-D-680 Type Il.Clean all non-electrical parts with a clean, lint–free cloth moistened with dry cleaning solvent(Federal Specification P-D-680).Inspect ON-OFF switch for cracked casing, corrosion, and burns or other evidence of shorting.Place switch in the ON position and check for continuity, using an ohmmeter. Ohmmeter shallindicate continuity. Check for open circuit with switch in the OFF position. Ohmmeter shall indicateopen circuit.Inspect circuit breaker for cracked casing, corrosion, and burns or other indications of shorting.Using an ohmmeter, check for open circuit across circuit breaker terminals. Ohmmeter shall indicateopen circuit. Depress circuit breaker button. Ohmmeter shall indicate continuity.Inspect indicator light lens for cracked or broken glass, corrosion, and other damage.Inspect lamp for cracked or broken glass, burned out filament and corrosion.Check indicator light base for cracks, corrosion, and burns.Inspect wiring harness for damaged connectors, wires, and terminals. Check individual wires forcontinuity using figure 5-2 as a guide.5-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!