10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>TO</strong> <strong>35C2</strong>-445-2NAVY NAVFAC P-8-624-<strong>34</strong>4-17. CIRCUIT INTERRUPTER TEST (SHORT CIRCUIT).a. General. A circuit interrupter is connected between the generator voltage reconnection system and thegenerator set output terminals to disconnect the generator output from the load and also to protect thegenerator from a short circuit. The circuit interrupter is operated from a current sensor external to theinterrupter.b. Apparatus. Instrumentation for measuring load conditions shall be as described and illustrated inMIL–HDBK-705. In addition, a non-inductive shunt, a short-circuiting switch, galvanometers matching networks,an oscillograph as described and illustrated in MIL-HDBK–705, Method 106.1, paragraph 106.1.3 andgalvanometers having a flat frequency response (flat within plus or minus five percent) from DC to 3,000 hertzwill be required.c. Procedure.(1) Preparation for Test.(a) Connect the load and instrumentation in accordance with the applicable figure of MIL-HDBK-705,Method 205.1, paragraph 205.1.10 for one voltage and frequency.(b) Connect the shunt, galvanometers matching network, oscillograph, and short-circuiting switch asillustrated in figure 512.1.1.(2) Test.(a) Start and operate the generator set at rated voltage, rated frequency and rated load.(b) Set the oscillograph time marker to a minimum of 0.01 seconds or use a 60 hertz timing trace setthe chart speed such that the individual peaks of the current waveform are clearly visible and adjustthe peak-to-peak rated current amplitude to a minimum of 0.5 inch for approximately 12millimeters).(c) Prior to closing the short-circuiting switch, record a portion of the steady state load for calibration.With the same load conditions record all instrument readings.(d) With oscillograph still recording the steady state current, close the short-circuiting switch.CAUTIONIf the circuit interrupter fails to operate within the specified time, remove the shortcircuit to prevent damage. Note the failure to operate on the data sheet. Failure toobserve this caution could result in damage to the equipment.(e) The generator set contains a short-circuit malfunction indicator, check and record its indication.(f) Repeat steps (a) thru (e) above for each possible short circuit condition (L1-L0,L2-L3,L1-L2-L3etc.).(g) Repeat steps (a) through (f) above for both voltage connections if applicable.d. Results(1) From the oscillograms taken in 4-18c (2) (d), determine the time between the indicated closure ofthe short-circuiting switch and the opening of the circuit interrupter. See figure512. 1.-II.4-17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!