10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>TO</strong> <strong>35C2</strong>-3-445-2NAVY NAVFAC P-8-624-<strong>34</strong>(a)(b)(c)With chassis cover (4, figure 3-130) removed, connect positive lead of voltmeter to heat sink whereCR1-CR3 are mounted. Connect negative lead to heat sink where CR4-CR6 are mounted. (Seeitem 17, figure 3–130).Apply 12 Vac (any frequency between 50 and 400 Hz) to pins A and B of connector J13.Voltmeter connected across heat sinks should indicate 9.3 Vdc.(d)Remove 12 Vac from pins A and B and connect to E and F, then to J and K. In each case, voltmetershould indicate 9.3 Vdc.(4) If the requirements of any test are not met, check components using figure 3-131 or 3-132 and table3-8 as a guide to locate the malfunction. Correct before installing the static exciter and voltageregulator assembly.g. Installation.(1) Position static exciter and voltage regulator to install Iockwasher (2, figure 3-130) and screws (1).(2) Connect electrical connectors to static exicter and voltage regulator.3-93. RELAY TABLE COMPONENTS ADJUSTMENTS.a. General. After maintenance has been performed on any of the relay table components, the appropriateadjustments shall be performed.b. Voltage Adjustment.(1) Position voltage adjustment rheostat R2 on generator set control cubicle to the approximatemidpoint.(2) Refer to the Operator and Unit Maintenance Manual and start the generator set.(3) Adjust voltage rheostat R2 to obtain generator assembly rated voltage at generator set load terminalboard.c. Paralleling Adjustments.(1)(2)(3)(4)(5)(6)(7)Refer to the Operator and Unit Maintenance Manual and connect a rated load to the generator setload terminal board.Start the generator set and operate at full rated load.Install the shorting plug in the paralleling receptacle.Place the operations switch on the generator set control cubicle in the PARALLEL position.Adjust reactive current adjust potentiometer R29 of the special relay assembly to provide a specialdroop of 3 percent.Adjust the load sharing adjust rheostat (R28) of the precise relay assembly until 4 to 6 VDC appearacross pins A and B of the paralleling receptacle. Insure that the positive lead of the meter isconnected to pin A. Repeat same procedure for all other generator sets to be paralleled. Voltagereadings must be identical on all generator sets to be paralleled to insure load sharing. Failure tomake this adjustment will result in load rejection and/or safety system shutdown.NOTEStep (6) pertains to precise generator sets only.Refer to the Operator and Unit Maintenance Manual and shut down the generator set.3-277

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!