10.07.2015 Views

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

ARMY *TM 9-6115-464-34 AIR FORCE TO-35C2-3 ... - Igor Chudov

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ARMY</strong> TM 9-<strong>6115</strong>-<strong>464</strong>-<strong>34</strong><strong>AIR</strong> <strong>FORCE</strong> <strong>35C2</strong>-3-445-2NAVY NAVFAC P-8-624-<strong>34</strong>3-63. LOAD MEASURING UNIT.a. Removal. Refer to the Operator and Unit Maintenance Manual for load measuring unit removalinstructions.b. DisassemblyNOTEDisassemble load measuring unit only as is necessary for inspection, testing, andreplacement of components.(1) Remove nut (1, figure 3-64), Iockwashers (2), flatwasher (3) to remove cover(4).(2) Remove screws (5), and Iockwashers (6) to remove connector (7).(3) Remove nut (8), lockwasher (9), flatwasher (10), screw (11), and connector bracket (12).(4) Remove nut (13), lockwasher (14), flatwasher (15), insulating washer (16), load resistor (17),insulating washer (18) and screw (19).(5) Remove screw (20), lockwasher (21), flatwasher (22), spacer sleeve (23), insulating washer (24),transformer (25), diode (26) from base (27).c. Cleaning and InspectionWARNINGSolvent, Dry Cleaning P–D-680, Type II is flammable and moderately toxic to skin,eyes and respiratory tract. Eye and skin protection required. Good general ventilationis normally adequate. Failure to observe this warning could result in servere personalinjury or death.WARNINGCompressed air used for cleaning and drying purposes can create airborne particlesthat may enter the eyes. Pressure shall not exceed 30 psig and use only with adequatechip guards and chipping goggles. Failure to observe this warning could result inservere personal injury or death.(1)(2)(3)(4)(5)(6)(7)(8)Clean all non-electrical metal parts in dry cleaning solvent (Federal Specification P-D-680) and drywith filtered compressed air.Clean electrical components with filtered compressed air and a soft bristle brush.Visually inspect cover connector bracket and base for cracks, corrosion, dents, and other damage.Inspect load resistor for cracks, corrosion, burns, and evidence of overheating.Inspect diodes for burns and other damage.Inspect electrical connector for bent or broken pins, burns, cracks, and other damage.Check all wiring for burned insulation, bare wires, broken or loose connections and other damage.If the wiring harness has sustained damage and requires repair or rebuild, refer to figure 3-65 forlayout, identification and material requirements and Appendix A for detailed soldering andreplacement procedures.3-152

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!