3-58 ENGINECRANKSHAFT AND CONRODCRANKSHAFT RUNOUT• Support the crankshaft with “V” blocks as shown, with the twoend journals resting on the blocks.• Set up the dial gauge, as shown.• Rotate the crankshaft slowly to read the runout.• Replace the crankshaft if the runout is greater than the limit. Crankshaft runout:Service Limit: 0.05 mm 09900-20607: Dial gauge (1/100 mm, 10 mm)09900-20701: Magnetic stand09900-21304: V-block set (100 mm)CONROD SMALL END I.D.• Using a small bore gauge, measure the inside diameter of theconrod small end. Conrod small end I.D.:Service Limit: 14.040 mm 09900-20602: Dial gauge (1/1 000 mm, 1 mm)09900-22401: Small bore gauge (10 – 18 mm)• If the inside diameter of the conrod small end exceeds thelimit, replace the conrod.