ELECTRICAL SYSTEM 9-17Measure the relay coil resistance between the terminals usingthe multi-circuit tester. If the resistance is not within the specifiedvalue, replace the starter relay with a new one. 09900-25008: Multi-circuit tester set Starter relay resistance: 3 – 6 ΩSIDE STAND/IGNITION INTERLOCK SYSTEMPARTS INSPECTIONCheck the interlock system for proper operation. If the interlocksystem does not operate properly, check each component fordamage or abnormalities. If any abnormality is found, replacethe component with a new one.SIDE-STAND SWITCHThe side-stand switch coupler is located behind the left frame.• Disconnect the side-stand switch coupler 1 and measure thevoltage between G and B/W lead wires. 09900-25008: Multi-circuit tester set Tester knob indication: Diode test ()ON(Side-stand up)OFF(Side-stand down)G(+ Probe)0.4 – 0.6 VB/W(- Probe)1.4 V and more(Tester’s battery voltage)NOTE:If the tester reads 1.4 V and below when the tester probes arenot connected, replace its battery.