4-34 FI SYSTEM DIAGNOSIS“C12” (P0335) CKP SENSOR CIRCUIT MALFUNCTIONDETECTED CONDITIONThe signal does not reach ECM for 3 sec. or more,after receiving the starter signal.POSSIBLE CAUSE• Metal particles or foreign material being stuck onthe CKP sensor and rotor tip• CKP sensor circuit open or short• CKP sensor malfunction• ECM malfunctionECMCKP sensorBGG/WG/BICKPCKPINSPECTIONStep 11) Turn the ignition switch to OFF.2) Lift and support the fuel tank. (5-3)3) Check the CKP sensor coupler for loose or poor contacts.If OK, then measure the CKP sensor resistance.14) Disconnect the CKP sensor coupler and measure the resistance.1 CKP sensor resistance: 142 – 194 Ω(Black – Green) 09900-25008: Multi-circuit tester set Tester knob indication: Resistance (Ω)