SERVICING INFORMATION 10-5DTC No.C44P0130C44P0135C49P1656C60P0480DETECTEDITEMHO2 sensorPAIR controlsolenoidvalveCooling fanrelayDETECTED FAILURE CONDITIONHO2 sensor output voltage is not inputto ECM during engine operation andrunning condition.(Sensor voltage 0.1 V)In other than the above value, C44(P0130) is indicated.The Heater can not operate so thatheater operation voltage is not supplyto the oxygen heater circuit, C44(P0135) is indicated.PAIR control solenoid valve voltage isnot input to ECM.Cooling fan relay signal is not input toECM.CHECK FORHO2 sensor circuit open orshorted to groundHO2 sensor lead wire/couplerconnectionBattery voltage supply to theHO2 sensorPAIR control solenoid valve, leadwire/couplerCooling fan relay, lead wire/couplerconnection