Electrical SystemXR620/621/842/1045/1245/1254/1267/1534/2050/30349-11 REPLACE A RELAYPerform the following procedure to replace a defective relay.– TASK REQUIREMENTS –PersonnelOne mechanicSpecial tools and equipmentSafety glassesParts and consumable materials Danger tags (2)RelayBe very careful when installing electrical center relays B through G, P/N 12068567.These five relays can easily be installed "upside-down" and will be inoperative ifinstalled incorrectly. Proper operation of each of these relays is essential for safeforklift operation. Refer to Figure 9-7 to ensure that the correct part number relay isinstalled in the correct socket and that the orientation of the relay is correct.Figure 9-7. Correct Installation of Relays B through G, P/N 12068567Service Manual Rev 01 – 05/10 9-18P/N 24933-000