Electrical SystemXR620/621/842/1045/1245/1254/1267/1534/2050/3034INITIAL SET-UP1. Park forklift on level surface.2. Set Travel Select lever to NEUTRAL (N).3. Set Parking Brake switch to ON.4. Retract boom and lower carriage. Allow sufficient space to open forklift covers.5. Set Ignition switch to OFF.6. Attach danger tags to steering wheel and ignition key. Refer to para. 2-5, for lockout-tagoutprocedure.REPLACE RELAY1. Open battery compartment cover.2. Set Battery Disconnect switch (Figure 9-8) to OFF.3. Remove three screws and washers from hinged console access panel (Figure 9-5).4. Gently lower console access panel to gain access to electrical center.5. Refer to Table 9-1 and Figure 9-5 for description and location of relays.6. Locate relay to be removed.7. Gently rock relay back and while applying upward pressure until relay releases from socket.8. Install new relay in socket.9. Reconnect black battery cable to negative (-) battery terminal.10. Start engine and check out systems and subsystems controlled by relay.11. Set Ignition switch to OFF.12. Raise console access panel and secure with three screws and washers.13. Close battery compartment cover.Service Manual Rev 01 – 05/10 9-19P/N 24933-000