D:04:02<br />

Fig. 19.<br />

Idle<br />

Adjustment<br />

Screw<br />

14. Note the Hydrocarbon reading at this point is<br />

no greater than 300 PPM.<br />

15. By closing one tap on the sample hose T-piece,<br />

and then the other check that the CO level in<br />

each bank of cylinders is 1% ± 0.3%.<br />

16. Re-connect the electrical connection to the<br />

oxygen sensor.<br />

17. Check that the duty cycle is operating at an<br />

average setting between 45-55%. Total swing<br />

on the needle must be less than ± 10%<br />

18. Re-connect the electrical connection to the<br />

oxygen sensor.<br />

19. Using the idle speed screw common to both<br />

banks adjust the idle speed to 775 ± 50 RPM.<br />

This will normally require the screw to be fully<br />

closed.<br />

Fuel Emission and Exhaust System<br />

©~<br />

20. Switch off the engine.<br />

Idle<br />

Mixture<br />

Screw<br />

21. Insert the tamper proof plug in the mixture hole<br />

in the metering unit and drive home.<br />

22. Remove exhaust sampling probes from the<br />

down pipe and insert the blanking plugs.<br />

Note:<br />

Section 203 of the Clean Air Act prohibits any<br />

person to remove or render inoperative any<br />

device specifically installed on the vehicle to<br />

ensure that the vehicle emission complies with<br />

control standards. It is essential therefore that<br />

components to the correct specification are<br />

fitted and specified engine settings are strictly<br />

adhered to.<br />