ENoxmmm SAFETY FEATuRES<br />

than regulatory limits. This function of the confinement and the HVAC system is<br />

not considered a function of an ESF. If the effluent control systems provide no<br />

unique accident consequence-mitigation function, the design bases and detailed<br />

discussions of the systems for normal operations should be given in Chapter 3,<br />

"Design of Structures, Systems, and Components," and Chapter 9, 'Awidliary<br />

Systems," of the SAR. Discussions and calculations of diffusion and dispersion of<br />

airborne radioactivity in both restricted and unrestricted environments should be<br />

given in Chapter 11, 'Radiation Protection Program and Waste Management."<br />

Areas of Review<br />

The reviewer should evaluate the following:<br />

* Design bases and functional description of the required mitigative features<br />

of the confinement ESFs, derived from the accident scenarios.<br />

* Drawings, schematic diagrams, and tables of important design and<br />

operating parameters and specifications for the confinement ESFs,<br />

including<br />

- seals, gaskets, filters, and penetrations (e.g., electrical<br />

experimental, air, and water)<br />

- necessary ESF equipment included as part of the confinement<br />

- fabrication specifications for essential and safety-related<br />

components.<br />

* .Discussion and analyses, keyed to drawings, of how the structure provides<br />

the necessary confinement analyzed in Chapter 13, with cross reference to<br />

other chapters for discussion of normal operations (such as Chapter 4,<br />

"Reactor Description," and Chapter 11),as necessary.<br />

* Description of control and safety instrumentation, including the locations<br />

and functions of sensors, readout devices, monitors, and isolation<br />

components, as applicable. (Design features should ensure operability in<br />

the environment created by the accident.)<br />

* Discussion of the required limitations on release of confined effluents to the<br />

environrnent. -.<br />

* Surveillance methods and intervals included in the technical specifications<br />

that ensure operability and availability of the confinement ESFs, when<br />

required.<br />

REV. 0, 2.6 6-S STANDARD REVIEW PLAN<br />

I REV.0, 2196 6-5 STANDARDREmIwPLAN