16 OTHER LICENSE CONSIDERATIONS<br />

This chapter contains guidance'for evaluating license considerations that do not<br />

belong elsewhere in the SAR. One of these considerations is prior use of reactor<br />

components. A recent consideration disaussed in this chapter is 'medical use of<br />

non-power reactors. There may be other topics that should appear in this chapter,<br />

but the applicant should determine these on a case -case basis.<br />

16.1 Prior Use of Reactor Components<br />

Areas ofReview -<br />

Prior use needs to be considered in'the case'of license renewal or in the case of the<br />

previous use of facility components and systems. Prior use need not have occurred<br />

at the reactor for which the applicant is seeking a license. At new facilities,<br />

components previously used at other reactor facilities may be used, or the<br />

Department of Energy may provide fuel that was used in another non-power<br />

reactor that was shut down. The applicant should consider how the component or<br />

system was used in the past.<br />

Areas of review should include the following:<br />

* ' selection of components and systems for consideration of prioruse<br />

* discussion of deterioration mechanisms for the items considered<br />

* analyses, tests, and measurements used to gauge deterioration<br />

* discussion of the preventive and corrective maintenance-program aind<br />

success of the program -<br />

* disaussion-and analysis of why components and systems for which prior use<br />

was considered are acceptable for continued operation during the requested<br />

license period<br />

Acceptance Criteria<br />

The acceptance criteria for the information on the prior use of reactor components<br />

should include the following:<br />

* -. The applicant should considerfacility 'components and systems for the<br />

effects of prior use.' Components and systems that have been used before<br />

and are significant to safety, such as fuel cladding, reactivity control<br />

REV 0,2/96 16-I ST4 aix, REVIEW PLAN<br />

REV 0, 2/9 16-1 STAMAM REVIEW PLAN