AuNARY SYSTEMS<br />

* No function or malfinction of the auxiliary system should interfere with or<br />

prevent safe shutdown of the reactor.<br />

* The technical specifications and bases applicable to an auxiliary system<br />

should be provided.<br />

Review Procedures<br />

The reviewer should compare the design and functional descriptions of the<br />

additional awdicary systems with the design bases. The reviewer should review the<br />

discussion and analyses of the functions and potential malfunctions with respect to<br />

safe reactor operation and shutdown, the effect on reactor safety systems, and the<br />

potential for the auxiliary system to initiate or affect the uncontrolled release of<br />

radioactive material.<br />

Evaluation Findngs<br />

This section of the SAR should contain sufficient information to support the<br />

following types of conclusions, which will be included in the staffs safety<br />

evaluation report:<br />

* The system has been designed to perform the functions required by the<br />

design bases.<br />

* Functions and potential malfunctions that could affect reactor operations<br />

have been considered in the design of the system. No analyzed functions or<br />

malfunctions could initiate a reactor accident, prevent safe reactor<br />

shutdown, or initiate uncontrolled release of radioactive material.<br />

* The technical specifications and their bases proposed in the SAR give<br />

reasonable assurance that the system will be operable, as required by the<br />

design bases.<br />

REv 0,2/96 9-17 STAIA1W REVIEW PLAN<br />

REV 0, 2/96 9-17 STAmDARD REvrEwPLAN