I<br />

CHAPTER 10<br />

The applicant should list the administrative controls used to protect facility<br />

personnel and the public from radiation or other possible hazards during<br />

the experimental program. Discussion should concentrate on the possibility<br />

that reactor and experiment operations may be conducted under separate<br />

authority and by different personnel. Areas of discussion should include<br />

access to experimental facilities and areas, lockout procedures,<br />

communications with reactor operating personnel, and alarms. The<br />

administrative controls should address basic protection and recovery<br />

procedures after a malfunction of experiments or experimental facilities.<br />

* The applicant should discuss the method used to assess the experimental<br />

materials and any limitations. How Regulatory Guides 2.2 and 2.4 2 were<br />

considered should be discussed. The assessment of experimental materials<br />

should include the following:<br />

- radioactive materials, including fissile materials, and radiological<br />

risks from radiation fields or release of radioactive material<br />

- neutron absorption and activation in trace elements and impurities<br />

- effects on reactivity, both positive and negative<br />

- explosive, corrosive, and highly reactive chemicals ><br />

- radiation-sensitive materials<br />

- flammable or toxic materials<br />

- cryogenic liquids<br />

- . unknown materials<br />

- radiation heating or damage that could cause experiment<br />

malfunction<br />

Review Procedures<br />

The reviewer should evaluate the composition of the experiment safety review<br />

committee and the methodology used for reviewing and approving experiments.<br />

Reviewed should be the use of references and the content of applicable technical<br />

specifications. The reviewer should compare the program under review with<br />

comparable programs at other non-power reactor facilities.<br />