CHAPTER 17<br />

Acceptance Criteria<br />

To be found acceptable, the format of the possession-only amendment should<br />

contain the topics addressed in the format and The acceptance criteria for the<br />

information on the application for the possession-only license amendment include<br />

the following-.<br />

The technical content of the possession-only license amendment application<br />

should be detailed and accurate to demonstrate, with reasonable assurance,<br />

that the health and safety of the facility stiff and the public will be'<br />

protected during the period of possession.<br />

* The application should contain an explanation of the need for the<br />

possession-only license amendment, a request for a specic duration, a<br />

discussion of the activities to be performed, an outline of the schedule for<br />

the time the amendment is in effect, and an explanation of any factors<br />

beyond the control of the licensee that affect the schedules.<br />

* The licensee should commit to a date to submit the applications for<br />

authorization to decommission and for license termination.<br />

* The application need only include (1) a proposal from the licensee to<br />

modify or remove the paragraph in the license that authorizes the reactor to<br />

operate and (2) a safety analysis.<br />

* The application may contain, at the discretion of the licensee, proposed<br />

additional license conditions; proposed technical specification, proposed<br />

physical security, emergency, and operator requalification plans; and<br />

additional safety analysis.<br />

* The possession-only safety analysis should contain discussions,<br />

descriptions, and analyses of the shutdown facility.<br />

* The safety analysis should state or refer to eisting provisions needed to<br />

control reactor-related radioactivity and to protect the health and safety of<br />

the public.<br />

* If the reactor was shut down unexpectedly because of factors beyond<br />

licensee's control, the application should describe the circumstances.<br />

These factors could include, for example, abrupt budgetary cobstraints or<br />

equipment failures.<br />

<strong>NUREG</strong>-1 537,P#.wr 2 17-6 REV 0,2/96<br />